Danfoss DHP-H User Manual page 25

Table of Contents

Advertisement

3 .2 .4
sub-menu TemPeraTure
In the TEMPERATURE menu you are able to view the
various temperatures that the installation has had. All
temperatures are stored 100 minutes (factory setting)
back in time so that they can also be displayed in the
form of graphs.
Menu text
OUTDOOR
ROOM
SUPPLY PIPE
RETURN PIPE
HOT WATER
INTEGRAL
BRINE OUT
BRINE IN
Description
Outdoor temperature
If ROOM shows 20°C the heat curve is
unaffected. If ROOM shows higher or
lower, this indicates that the heat curve
has been adjusted up or down to change
the indoor temperature.
Indicates the measured supply tempera-
ture of the heating system. (The desired
value is shown between brackets.)
Indicates the measured return tem-
perature of the heating system. (The
highest permitted temperature is shown
between brackets.)
Indicates measured hot water tem-
perature. (The temperature at which
hot water production starts is shown
between brackets.)
Heat production is controlled by a calcu-
lated demand that is automatically cal-
culated when the installation is in opera-
tion. The integral is the heat system's
energy balance.
The temperature of the brine when it
returns to the heat source.
The temperature of the brine from the
heat source.
TEMPERATURE
OUTDOOR
ROOM
SUPPLY PIPE
RETURN PIPE
HOT WATER
INTEGRAL
BRINE OUT
VUBMA102
-20°C
41(70)°C
38(48)°C
55(44)°C
Adjusted by:
By the customer,
if necessary.
Not adjustable
(The computer calcu-
lates the temperature
required to maintain the
indoor temperature.)
Authorized installer.
Adjusted for each instal-
lation.
Not adjustable
Not adjustable
Not adjustable
Not adjustable
Danfoss – 2
20°C
-660
-7°C