Danfoss DHP-H User Manual page 24

Table of Contents

Advertisement

3 .2 .3
sub-menu HeaTCurVe
In the HEATCURVE menu the settings that affect the
indoor temperature are made. For further informa-
tion, see the "About your heat pump" section.
Menu text
CURVE
MIN
MAX
CURVE 
CURVE 0
CURVE - 
HEATSTOP
REDUCTION
Danfoss – 2
Description
The set value indicates the supply line
temperature of the water that is trans-
ported to the heating system at an out-
door temperature of 0°C.
Sets the lowest permitted supply tem-
perature.
Sets the highest permitted supply tem-
perature.
Used to adjust the heat curve at an out-
door temperature of +°C.
Used to adjust the heat curve at an out-
door temperature of 0°C.
Used to adjust the heat curve at an out-
door temperature of -°C.
This function stops all production of
heat when the outdoor temperature is
equal to, or higher than, the set heat stop
value.
The temperature can be lowered using
an outside timer. The control computer
determines the drop.
VUBMA102
HEATCURVE
CURVE
MIN
MAX
CURVE 5
CURVE 0
CURVE -5
HEATSTOP
Adjusted by:
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
By the customer,
if necessary.
40°C
22°C
70°C
0°C
0°C
0°C
17°C