Start
You will need:
• Multi-Purpose Oil
• Rags
ImPORTanT: Store the
unit indoors with the
power cord wrapped
around the handle.
4
5 SECONDS
4. Cover the outlet valve with a rag.
Turn power ON and let the pump
run for five seconds.
English
1
MULTI-PURPOSE
1. Carefully tilt the sprayer on
OIL
its back.
Squeeze the ears (a) on
the suction tube clip and
slide out of the inlet fitting.
5
ON
OFF
5. Turn power OFF.
2
(a)
2. Remove the suction tube.
Using a wrench, remove
the spray hose.
6
6. Replace suction tube. Insert
suction tube into the inlet valve
housing and secure with the
suction tube clip (b).
20
3
3. Careully tilt the sprayer upside-down.
Squirt approximately 2 ounces of Multi-
Purpose Oil into the inlet fitting.
7
(b)
7. Wipe entire unit, hose,
and spray gun to remove
accumulated spray material.
MULTI-PURPOSE