Adjustment
1. Attach the front cover assy..
2. Remove the presser foot, the needle plate B and the needle plate A, and then remove the inner rotary hook.
3. Start the test mode.
4. Select the pattern number "02" (3-point needle drop mode).
5. Move the needle to the left with the
6. Turn the pulley by hand and move the needle to its lowest position.
7. Remove the base cover.
8. Loosen the 2 socket set screws (CP, M5 x 5) on the lower shaft pulley D.
9. Turn the outer rotary hook by hand and adjust the right edge of the needle aligns with the outer rotary hook point
when raising up the needle bar 3.1 to 3.3mm from its lowest position.
10. Tighten the 2 socket set screws (CP, M5 x 5) on the lower shaft pulley D.
11. Attach the base cover.
Base cover
3.1 - 3.3mm
Needle bar rising
(Reverse stitch button), and then turn the power off.
The right edge of the needle aligns with the
outer rotary hook point when raising up the
needle bar 3.1 to 3.3mm from its lowest position.
Socket set screws
(CP, M5 x 5) (2pcs.)
Lower shaft pulley D
4 - 9