Main unit
20
Power PCB assy. removal
1. Remove the ZPM lead wire assy. 1 from the guide parts 2 of the
insulation cover.
2. Remove screws 1 and 2 (1pc. /2 pcs.), and then remove the power PCB
assy. 3.
3. Disconnect the main motor lead wire 4 and the inlet assy. connector 5.
*Key point
• Hold the hook on the inlet assy. connector 5 and pull it out.
20-1
Power PCB assy. disassembly
1. Disconnect the power lead wire assy. connector 1 from the power PCB
assy. 2.
2. Remove the screw 1, and then remove the power plate spring 3 from the
power PCB assy. 2.
3. Remove the screw 2, and then remove the insulator sheet 4 and the
power PCB assy. 2 from the insulation cover.
21
Inlet assy. removal
1. Remove the screw 1, and then remove the inlet assy. 1 from the rear
cover assy..
2 - 14
Main parts
2
4
3
1
2
5
3
1
1
2
2
4
1
1
1