9. Contrast adjustments-AV
Equipment
Oscilloscope.
Input mode
AV.
Input signal
16 step gray scale signal
Adjustment :
Enter the mode of "service adjustment".
Adjust each following item so that the amplitude of part A may be min-
imum amplitude.
Group Item
Probe
210-
4
TP531 (Green contrast adjustment)
210-
5
TP561 (Red contrast adjustment)
210-
6
TP501 (Blue contrast adjustment)
A
Black Level
Equipment
Input mode
Input signal
Picture condition
Adjustment :
Enter the mode of "service adjustment".
Adjust each following item.
Group
210-
210-
210-
Pedestal
Level
Equipment
Input mode
Input signal
Adjustment :
Enter the mode of "service adjustment".
Adjust each following item.
Group
200-
200-
200-
-41-
10. Panel driving signal adjustments -AV
Oscilloscope.
AV.
16 step gray scale signal
Normal.
Item
Probe
Adjustment part.
7
TP531
Amplitude of part A
8
TP561
Amplitude of part A
9
TP501
Amplitude of part A
11. Panel driving signal adjustments -PC
Oscilloscope.
Computer
16 step gray scale signal
Item
Probe
Adjustment part.
7
TP531
Amplitude of part A
8
TP561
Amplitude of part A
9
TP501
Amplitude of part A
Adjustment or adjustment value.
10.5 ± 0.05Vp-p
10.5 ± 0.05Vp-p
10.5 ± 0.05Vp-p
A
Adjustment or adjustment value.
10.5± 0.05Vp-p
10.5 ± 0.05Vp-p
10.5 ± 0.05Vp-p
A