System Control
Are you thinking about turning
on the projector without the
lamp cover?
Remember that the interlock
Is the fuse (F901) blown?
switch is opened during disas-
The fuse may be opened
sembling the cabinet. The projec-
when either the LAMP indica-
tor can't be turned on. (Some of
tor or the READY indicator
the service personnel forget it
isn't Illuminated. Check the
often.) When you turn on the pro-
fuse. For continued safety,
jector without cabinet, press and
hold the lever of the interlock
replace it with a new fuse of
the same type.
switch.
Hot circuit
FUSE
F901
AC-INPUT
Check that the
POWER FAIL sig-
nals are correct.
L : Abnormality
Are
the
LAMP
indicator(red) and READY
indicator(green) light?
If the LAMP and READY
indicators are not illuminat-
ed, check the primary cir-
cuit and S5V of standby
power supply circuit.
INDICATORS
* NO POWER -1
Is the Interlock switch
opened?
When the lamp cover isn't
attached correctly or the boss
inside the lamp cover is bro-
ken, the projector can't be
turned on. Check the boss
and the Interlock switch
(SW902). Refer to figure on
page 4.
INTERLOCK SW
SW902
FANS
FANS
Check that the Fan
on/off signal is cor-
rect.
L : Abnormality
LAMP
REPLACE
WARNING
TEMP.
READY
LAMP
-22-
Troubleshooting
Refer to page 24.
ASS'Y POWER
DC out
16V /9V /6.25V /-6V
POWER
CONTROL
FAN
ON/OFF
CONTROL
I / O
EXPANDER
SUB POWER
Check that the IIC
Bus signals for fan
control are correct.
Power sw
Power sw
ON
OFF
Power on/off
Fan on/off
PFC on/off
Ballast on/off
Cooling time after power off.
400~600ms(Stability period of PFC.)
AC
Always
DC out
SWITCH
Switched
Check that the
Vcc-voltages are
correct.
Check that the POWER
ON/OFF signal is correct.
L : Abnormality
CPU IC801
and
I / O
EXPANDER
IC1831
Timing chart