Shut stove off if the firepot overfills with pellets or the flame becomes dark and sooty. This indicates 
poor fuel combustion and the cause should be investigated and remedied. (See Trouble Shooting tips for 
possible causes) 
It's critical for proper operation that you maintain unobstructed airflow through the intake vents of the 
stove. The viewing door and ash pan must be closed and latched during operation.  Never abuse the 
door by slamming it shut. 
The pellet appliance exhaust system works with negative combustion chamber pressure and positive 
chimney pressure.  The exhaust system must be completely airtight and properly installed. All exhaust  
vent joints must be tightly sealed with gasket and or HI‐TEMP 
sheet metal screws per joint.  
For required periodic maintenance and cleaning refer to  Section #6 "Maintenance & Required Cleaning" 
of this manual.      Failure to maintain your stove may lead to poor operation and exhaust fume leakage 
into your home.  Only use replacement components that are authorized by Hearthland Products, LLC. 
Always disconnect power from your stove before performing any maintenance. Power Cord must be 
unplugged. Pushing "OFF" Touch Pad does not disconnect all power to the stove. 
To avoid accidental fire, DO NOT place any flammable item on or near the stove.  
To prevent burns, maintenance or cleaning, should only be performed on a cool stove.  
Hearthland Products grants no warranty, implied or stated, for the maintenance or installation              
of your stove, and assumes no responsibility whatsoever of any consequential damage to               
stove or its surroundings. 
S
 L
AFETY
ISTING
 
In accordance with the procedures and specifications listed in ASTM E1509‐04, ULC/ORD‐C1482‐M1990, and ULC S627‐
00 for solid fuel room stove, Hearthland Products, pellet stoves have  been independently tested and listed by Omni Test 
Laboratories, Inc. Portland, Oregon (an accredited testing laboratory). It is tested and listed for residential installation 
according to current national and local building 
codes as: 
FREESTANDING ROOM HEATER 
ROOM HEATER, PELLET FUEL‐BURNING TYPE, 
ALSO FOR USE IN MOBILE HOMES 
 
The Safety Listing Label is located on the rear 
panel . Read the label carefully. It contains infor‐
mation about the installation and operation of 
your stove.   The stove's serial number is located 
on the safety label. Your serial number is pre‐
ceded by a "OMNI‐" (example OMNI‐00000). (see 
diagram). 
VS0952_E 
 
IMPORTANT 
12/30/2009 
RTV silicone sealant, and at least 3 
(550°F) 
 5 

Advertisement

Table of Contents
loading

This manual is also suitable for:

HiawathaNokomis

Table of Contents