FOR MOBILE HOME INSTALLATIONS, OUTSIDE AIR INTAKE IS REQUIRED.
•
WARNING: DO NOT INSTALL STOVE IN SLEEPING ROOM.
•
CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND
CEILING / ROOF MUST BE MAINTAINED!
•
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
Hearthland Series
Your
appliance has been tested and listed for mobile home installation. It may be
installed in a mobile home as a "Free Standing Stove" or a "Hearth Stove", see detailed install and clearance re‐
quirements in these sections as they imply there. (See Section # 2.6 "Outside Air Intake")
In addition to all previously detailed installation requirements, mobile home installations must meet
the following requirements:
•
Permanently bolt your stove to the floor using base vent holes.
•
Electrically ground your stove or the pedestal to the steel frame of the home. Use a number 8 gauge copper wire,
or equivalent.
•
The stove must have a permanent outside air source with a ¼ inch screen over the inlet.
•
For transportation all chimney/vent above the mobile home must be removed.
•
Chimney/PL Vent must be 3" or 4" PL Vent and must extend a minimum or 36" above the roofline of the
mobile home and must be installed using a UL / ULC listed ceiling fire stop (J) and rain cap (L), figure 26.
A
B
C
D
E
F
G
H
I
J
K
L
VS0952_E
M
H
OBILE
OME
IMPORTANT
Floor Pad
Combustion Air Intake
Fresh Air Duct
Fresh Air Hood
Stove Exhaust
Pipe Adapter
Clean Out Tee
Tee Support Bracket
Pipe
Fire stop Spacer / Ceiling Sup‐
port
Roof Flashing / Storm Collar
Rain Cap
12/30/2009