O
PERATING
STARTING STOVE:
1)
Verify the following before each starting, :
⇒
The burn grate is clean & properly seated.
⇒
The door is properly closed.
⇒
The hopper contains wood pellets and the lid is closed.
⇒
The electrical cord is plugged in.
2)
Adjust the air inlet damper to be open approximately 1/4".
3)
Press START on the ITC touch pad and the following will
happen:
⇒
Convection blowers (room heat) will start at full power for a
few seconds and then drop to the fan speed setting indicated with LED's on the touchpad.
⇒
Combustion (exhaust) blower will start at full power for several seconds, then will automatically adjust to
facilitate ignition.
⇒
The Heat Level LED will flash indicating the current heat setting.
⇒
The IGNITER LED will light and the Auto‐Igniter will begin to glow as viewed through the burn grate.
⇒
The FUEL FEED LED will light intermittently indicating when the auger is turning and fuel is being fed to
the burn grate. The auger on time is 3 seconds and the off time will vary. Note: If the hopper and auger
were empty, it will take longer for pellets to begin falling into the burn grate.
⇒
The pellets will automatically ignite in approximately 3 to 7 minutes.
⇒
After the flame has stabilized and the ITC detects a steady burn, the controller will exit start‐up mode and
enter burn mode. The Igniter light will go out and the heat setting LED will stop flashing and stay on
steady.
SHUTTING OFF STOVE:
1)
Press "OFF" on the touch pad and the following will happen:
⇒
The Auger will stop dispensing fuel to the burn grate.
⇒
The "FAN SPEED" LED will flash.
⇒
The combustion (exhaust) blower will the combustion & convection blowers for 10 minutes or
until the stove exhaust cools below 120° F, at which point all components will turn off.
NOTE: If "OFF" is pressed unintentionally, simply press start on the touchpad and the stove will re‐
sume operation after it completes a short hot start sequence.
•
Never empty pellets from the burn pot into the hopper. Pellets that may appear cool may retain
enough heat to ignite other pellets resulting in smoke or fire damage.
•
If stoves fails to light within 15 minutes, the controller will shut off. If this happens, empty burn grate
and begin the starting procedure again. If stove fails to ignite a second time, disconnect stove power
and contact your dealer.
•
Stove paint is not fully cured until the stove is fired (3) times. During this curing process fumes will be
given off. Open windows and doors and use fans to provide fresh air while curing. Fumes will not be
present after paint fully cures. (See Section #2.1 "Pre‐Installation Checklist")
•
Never use liquid or volatile fire starters to start a fire in your stove! Do not in‐stall or operate your
stove in any room where any liquid or volatile fuels or any other highly combustible items are in the air
VS0952_E
I
NSTRUCTIONS
IMPORTANT
12/30/2009
(C
)
(C
)
ONTINUED
ONTINUED
25