Hearthland Itasca Installation And Operation Manual page 29

Pellet stove
Table of Contents

Advertisement

O
PERATING
 
NOTE:  To operate in either of the two thermostat modes, an optional thermostat kit must be purchased  and 
installed.  Thermostats compatible with your Hearthland stove are available from your local dealer.  
 
Thermostat Modulated Mode has advantages over Thermostat ON/OFF mode.  
More consistent room temperature will be maintained. 
Life of the Auto Igniter is increased, seeing fewer ignition cycles.  
The stove will tend to operate primarily at the low setting, resulting in more efficient use of energy  to 
maintain desired temperature setting. 
THERMOSTAT MODULATED MODE (HIGH‐LOW)  
This feature of your stove allows for modulated heating with use of a thermostat connected to the ITC.  In this 
mode your stove will run at the heat setting 2,3 or 4 when the thermostat calls for more heat, and drop to heat 
setting 1 when the set room temperature is achieved.   This makes your stove more responsive to your heating 
needs, and eliminates the need to re‐ignite with each heat demand cycle. 
 
 
TO START 
To operate in High Low thermostat mode,  press the START touch pad to activate the stove as  described 
in section #4.7 "Starting Stove & Shutting Off Stove". 
Select desired HIGH heat output level (2,3 or 4 position) by pressing the START / HEAT LEVEL touch pad.  
Select desired FAN SPEED setting as described in section #4.8 "Setting Fan Speed".   
Once settings are selected your high HEAT LEVEL and FAN SPEED LED's will flash while your stove goes 
through the initial start up cycle.  
Upon completion of startup cycle, the stove will cycle between HEAT LEVEL 1 
and the high setting selected (2,3 or 4 position)  the HEAT LEVEL indicator 
light will light indicating its current setting.  
 
TO SHUT DOWN 
To turn off the appliance press the OFF touch pad per section #4.7 "Starting Stove & Shutting Off Stove". 
THERMOSTAT ON‐OFF MODE
In this mode the  thermostat is set at the desired room temperature.  If the room temperature drops below the 
level on the thermostat the stove will automatically light and operate at HEAT LEVEL setting 2,3 or 4 until the 
temperature setting is reached at which time the stove will shut down.  
 
TO START 
Press START to activate the stove per section #4.7 "Starting Stove & Shutting Off Stove". 
Select desired HIGH heat output level (2,3 or 4 position) by pressing the START / HEAT LEVEL touch pad.         
NOTE: The Heat Level can be adjusted between setting 2‐4 at any time. 
Select desired FAN SPEED setting as described in section #4.8 "Setting Fan Speed".   
 
 
TO SHUT DOWN 
To turn off the appliance press the OFF touch pad per section #4.7 "Starting Stove & Shutting Off Stove". 
 
Note:  If in THERMOSTAT ON‐OFF MODE the stove turns off and on frequently,  we suggest you turn the HEAT 
LEVEL to a lower setting so that it stays on for longer periods. This will result in a more consistent room tempera‐
ture.  
VS0952_E 
 I
NSTRUCTIONS
12/30/2009 
 
 
(C
)
(C
)
ONTINUED
ONTINUED
 29 

Advertisement

Table of Contents
loading

This manual is also suitable for:

HiawathaNokomis

Table of Contents