Earth Rotection; Locating Stove - Hearthland Itasca Installation And Operation Manual

Pellet stove
Table of Contents

Advertisement

H
LOCATING STOVE: 
Keep in mind the following placement concerns; venting obstructions, outside air, electrical out‐
let, wall thermostat, heat distribution, traffic patterns and room use/size. 
If the stove is placed in a location where the ceiling height is less than 7', it must follow the re‐
quirements in the section "Alcove Installation". 
Although not required for safety reasons, it is strongly suggested that sufficient space be pro‐
vided (a minimum of 24") on each side of the appliance and at the back of the appliance to en‐
able servicing the unit if necessary.  If this space is unavailable, a provision must be made to en‐
able sliding the appliance out.   
 
 
MINIMUM CLEARANCE TO WALLS & COMBUSTIBLES: 
2"  From Back Of Stove  
6"  From Side of Stove  (8" in Canada) 
6" From Front Of Stove  (18" in Canada) 
16"  From Top Of Stove (8" in Canada) 
3"  From PL Vent to Combustibles 
2"  From Back Corner of Stove  
36"  to drapes, doors, anything that can swing toward stove. 
 
 
REQUIREMENTS FOR FLOOR PROTECTION : 
Stove and floor protection must be installed on a level secure floor. 
It is important for your appliance to be level.  Leveling should occur below the floor protection 
pad. 
The stove must be installed on a non‐combustible floor protector (i.e. sheet steel with cement, 
tile slate) extending the full width and depth of the stove. 
 
FLOOR PROTECTION MUST EXTEND: 
6" beyond front of the stove ( 18" in Canada)  
6" beyond sides of the stove ( 8" in Canada)  
2" beyond rear of the stove and to either side of chimney tee.  
 
 
 
 
 
 
VS0952_E 
 P
EARTH
ROTECTION
12/30/2009 
 & C
LEARANCES
  
 
 15 

Advertisement

Table of Contents
loading

This manual is also suitable for:

HiawathaNokomis

Table of Contents