Jandy CL Versa-Plumb Series Installation And Operation Manual page 9

Cartridge pool filters
Hide thumbs Also See for CL Versa-Plumb Series:
Table of Contents

Advertisement

Note: Do not
overtighten.
Figure 7.
Sweep Elbow
b.
Be sure there is a minimum distance of
7½ inches between the center of the pump
outlet port and the fi lter inlet bulkhead to
accommodate the sweep elbow(s). See
Figure 8 for recommended installation
confi guration.
NOTE
The SHP pump shown in Figure 8 is for reference
only. The Jandy sweep elbow also works with the
MHP and PHP series pumps.
NOTE
Be sure to use 2" or 2½" schedule 40 PVC pipe.
c.
Clean the cut ends of the pipe and both ends
of the sweep elbow(s) with an appropriate
NSF
®
approved All Purpose cleaner/primer.
Glue the sweep elbow(s) onto the cut pipe
ends using an appropriate All Purpose NSF
approved adhesive/glue.
NOTE: Zodiac recommends Weld-On 724 PVC to CPVC
Cement to glue Schedule 40 PVC.
d.
After the glue is cured, close the pressure
relief valve on top of the fi lter, start the
system and check for proper water fl ow.
LXi Heater
Figure 8.
LXi Heater, CV Filter and SHP Pump Sweep Elbow Installation
Cartridge Pool Filters - CL and CV Series Filters
Sweep Elbow
P/N SEAQL1001
6.
Make all plumbing connections in accordance
with local plumbing and building codes. Filter
connections are provided with an o-ring seal. To
avoid damage to the o-rings, use only a silicone
base lubricant on the o-rings. Do not use pipe joint
compound, glue or solvent on inlet/outlet union
coupling nuts.
7.
Keep piping tight and free of leaks. Pump suction
line leaks may cause air to be entrapped in fi lter
tank or loss of prime at the pump. Pump discharge
line leaks may show up as dampness or jets of
water.
8.
Support the inlet/outlet pipes independently to
prevent any undue strains on the fi lter valve.
9.
Connect the pipes using the unions supplied with
the fi lter. Do not use Tefl on tape or pipe dope on
any unions. Assemble the unions dry and hand
tighten. See Figure 6.
10. If desired, the CV fi lter drain can be plumbed
using a Jandy universal union. The plumbing must
contain a ball valve as shown in Figure 6.
Be sure that all provisions for wastewater disposal
meet local, state or national codes. During any
draining process, one hundred gallons (100
gals.) or more of pool water will be discharged.
CL and CV (Cartridge) Filters are not subject to
backwashing. Do not discharge water where it will
cause flooding or damage.
7½"
Minimum
CV Filter
Pump
CAUTION
Sweep Elbow
P/N SEFL1002
SHP
Page 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents