Page 1
Jandy Diatomaceous Earth Pool Fil ters DEV Series Fil ters WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualifi ed in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists.
Section 8. Troubleshooting ....... 12 Filter Location ......5 Section 9. Parts List and Exploded View ..14 Anchor Bracket Installation ..5 Jandy DEV Filter Parts List ..14 Filter Preparation ......5 Exploded View of Jandy Filter Plumbing ......6 DEV Filter ........
(air will have stopped fl owing from the air release valve). Whenever installing the fi lter clamp follow Section 3.5 of this manual, "Clamp Installation, DEV Series". Once service on the circulation system is complete, follow Section 4 of this manual, "Start-up and Operation".
This manual contains information for the proper product failure or also cause the fi lter lid to be blown installation and operation of the Jandy DEV Series off, which can result in death, serious personal injury, Diatomaceous Earth (DE) Filters. Procedures in this or property dam age manual must be followed exactly.
Diatomaceous Earth Pool Filters - DEV Series Filter Page 5 Section 3. Installation Instructions If the fi lter needs to be located above the water level of the pool, it can be raised 2.5 ft. without affecting the pump effi ciency. A check valve is WARNING recommended on the suction line to the pump.
fi lter tank (located in the system, this fi lter will operate in a safe manner. accessory bag): From Outlet Port Jandy Heater Spa Make Up To Inlet Port Jandy Pump Jandy...
Diatomaceous Earth Pool Filters - DEV Series Filter Page 7 Support the inlet/outlet pipes independently to Housing prevent any undue strains on the fi lter's two (2) or three (3) port diverter valve. O-Ring Tank Adapter 10. Connect the pipes using the unions supplied with the fi...
Page 8 WARNING Changing the two (2) or three (3) port diverter valve handle while there is pressurized air in the system can cause product failure or also cause the fi lter Clamp Ring lid to be blown off, which can cause death, se ri ous personal injury or property damage.
Diatomaceous Earth Pool Filters - DEV Series Filter Page 9 Table 2. DE Slurry Mixture Watch the pressure gauge to be sure that the pressure does not exceed 50 psi in the fi lter for Model DE Quantity No. of 1 lb.
Page 10 While the DE fi lter grid assembly is out of the WARNING fi lter tank, rinse the inside of the tank with water. NEVER attempt to assemble, Replace drain plug. dis as sem ble or adjust the fi lter when Gently rinse the grids with water.
Diatomaceous Earth Pool Filters - DEV Series Filter Page 11 Place the tie rod knob on the tie rod and tighten. 6.2 Backwashing Tighten until the fi lter grid assembly is snug. With the fi lter pump off, set the backwash valve Do not overtighten.
Page 12 Section 8. Troubleshooting WARNING For a list of common problems and solutions, see Working with muriatic acid can be dangerous. When the Troubleshooting Guide on the following page. cleaning fi lter grids, always wear rubber gloves and eye protection. Add acid to water, do not add water Zodiac recommends that you call a service to acid.
Page 13
Diatomaceous Earth Pool Filters - DEV Series Filter Page 13 Table 4. Troubleshooting Guide Fault Symptom Possible Problems Solutions Water is not clear. Insufficient disinfectant level. Check and adjust disinfectant level. Incorrect pool chemistry. Test and adjust water chemistry. Heavy bathing and/or dirt loads.
Page 14 Section 9. Parts List and Exploded View 9.2 Exploded View of Jandy DEV Filter 9.1 Jandy DEV Filter Parts List Part Description Handle Assembly w/ Hardware (set of 2) R0357100 Handle Hardware (set of 4) R0359900 Gauge/Air Release Assembly...
Diatomaceous Earth Pool Filters - DEV Series Filter Page 15 Section 10. Head Loss Curves 10.1 Jandy® DEV Filter Design Head Loss Curves DEV48 DEV60 Design Design Head Pressure Loss Drop (ft head) (psi) Flow Rate (gpm)