Page 1
® Element Cartridge Pool and Spa Filters Models CS100 and CS150 WARNING FOR YOUR SAFETY - This product must be installed and serviced by a professional pool/ spa service technician. The procedures in this manual must be followed exactly. Improper installation and/or operation can create dangerous high pressure which can cause the filter lid to be blown off, possibly causing death, serious injury or property damage.
• Water temperature for test must NOT EXCEED 100°F (38°C). • Limit test to 24 hours. After test, visually check system to be sure it is ready for operation. Notice: These parameters apply to Jandy equipment only. For non-Jandy equipment, consult equipment manufacturer. 1.2 General Safety Instructions...
Use Jandy universal unions to connect each at 707.776.8200 ext. 237. For address information see component of the water conditioning system for back cover. future servicing. All Jandy filters come with these type of fittings. 2.2 Description When performing hydrostatic pressure tests or...
Page WARNING Outlet Port Water discharged from an improperly positioned filter or valve can create an electrical hazard which can cause death, serious injury or property damage. 13” CAUTION Maintain your pressure gauge in good working order. The pressure gauge is the primary indicator of how Drain 20 1/8”...
11. Install ¼ x 2¼" Stainless Steel Tapcon® screws To reduce pressure losses, 2" (minimum) piping and tighten. is recommended for plumbing the system. Drain Outlet Inlet Port Port Jandy Heater Inlet Port Spa Make Up Jandy Pump Jandy Filter From Pool Drain Jandy Waterfall...
Page 3.4 Locking Ring/Tank Top Assembly Section . Start-Up and Operation Installation WARNING Be certain the o-ring is in position in the upper NEVER start pump while standing tank half. Press the filter lid over the lower half within five (5) feet of the filter. Starting until seated.
Cartridge Filters - CS Series Filter Page Section 5. Filter Disassembly and Assembly Release Valve WARNING Tank Top NEVER attempt to assemble, disassemble or adjust the filter when there is pressurized air in the system. Locking Starting the pump while there is Ring any pressurized air in the system can cause the filter lid to be blown...
Keep the pressure gauge in good working order. Loosen the drain plug at the base of the filter to If you suspect a problem with the gauge, Jandy ensure the tank is empty. recommends you call a qualified service technician to do any work on the filter/pump system.
Page 11
Cartridge Filters - CS Series Filter Page 11 If the obstruction or debris can not be removed or the breather tube is damaged, STOP using the filter immediately and replace the breather tube assembly. WARNING If the breather tube is not fully seated or is damaged or clogged, trapped air can cause the filter lid to be blown off which can result in death, serious personal...
Section 8. Troubleshooting For a list of common problems and solutions see the Troubleshooting Guide below. Jandy recommends that you call a qualified service technician to do any work on the filter/pump system. For technical service call 707.776.8200, ext. 260.
Top Housing Assembly CS100, CS150 R0461900 O-Ring, Tank Top R0462700 Inlet Diffuser with Locking Tab R0462100 Cartridge Element, 100 Sq. Ft., CS100 R0462200 Cartridge Element, 150 Sq. Ft., CS150 R0462300 Tailpiece, Cap and Union Nut Set R0461800 (Set of 3), 2" x 2½"...
DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities of water. LIMITATION OF LIABILITY: This is the only warranty given by Jandy Pool Products, Inc. No one is authorized to make any other warranties on behalf of Jandy Pool Products, Inc. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY.
Need help?
Do you have a question about the CS100 and is the answer not in the manual?
Questions and answers