Message
Timer chip
counter 2 failed.
TPM
configuration
operation
honored. System
will now reset.
TPM
configuration
operation is
pending. Press
(I) to Ignore OR
(M) to Modify to
allow this change
and reset the
system.
WARNING:
Modifying could
prevent
security.
TPM failure.
Unable to launch
System Services
image. System
halted!
Unexpected
interrupt in
protected mode.
Causes
Faulty system board.
A Trusted Platform Module
(TPM) configuration
command has been
entered. The system will
reboot and execute the
command.
This message displays
during system restart after
a TPM configuration
command has been
entered. User interaction is
required to proceed.
A TPM function has failed. See "Getting Help" on
System halted after F10
keystroke because System
Services image is either
corrupted in the system
firmware or has been lost
due to system board
replacement.
Improperly seated memory
modules or faulty keyboard
or mouse controller chip.
Corrective Actions
See "Getting Help" on
page 135.
Information only.
Enter I or M to proceed.
page 135.
Restart the system and update
the Dell USC repository to the
latest software to restore full
functionality. See the Dell
USC user documentation for
more information.
Reseat the memory modules.
See "Troubleshooting System
Memory" on page 119. If the
problem persists, see "Getting
Help" on page 135.