Dell PowerEdge T110 II Owner's Manual page 28

Hide thumbs Also See for PowerEdge T110 II:
Table of Contents

Advertisement

Message
The following
DIMMs should
in
match
geometry:
x,x,...
The following
DIMMs should
in rank
match
count:
x,x,...
The following
DIMMs should
match in size:
x,x,...
The following
DIMMs should
in size
match
and geometry:
x,x,...
The following
DIMMs should
in size
match
and rank count:
x,x,...
Thermal sensor
not detected on
x.
Time-of-day
clock stopped.
Time-of-day not
set - please run
SETUP program.
28
About Your System
Causes
Invalid memory
configuration. The
specified memory modules
do not match in size,
number of ranks, or
number of data lanes.
A memory module without
a thermal sensor is installed
in the specified memory
slot.
Faulty battery or faulty
chip.
Incorrect Time or Date
settings; faulty system
battery.
Corrective Actions
Ensure that the memory
modules are installed in a valid
configuration. See "General
Memory Module Installation
Guidelines" on page 86.
Replace the memory module.
See "System Memory" on
page 86.
See "Troubleshooting the
System Battery" on page 116.
Check the Time and Date
settings. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 35. If the problem
persists, replace the system
battery. See "System Battery"
on page 97.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents