INSTALL SUPPLY CABLE TO THE MACHINE

WARNING!
!
THE PROTECTIVE CONDUCTOR MUST BE LONGER SO THAT WHEN THE CABLE IS PULLED OUT
ACCIDENTALLY, THIS CONDUCTOR IS DISCONNECTED AS THE LAST ONE!
1. Green-yellow - protection conductor PE
2. Brown - phase conductor
3. Blue - neutral conductor N
1AC 220-240V / 50/60Hz
If the cable is attached from above, it is recommended to make a sagging on the cable in front of its entry
into the cable bush. In this way an ingress of the running condensed water into the bush and/or machine
can be avoided.

WATER SUPPLY CONNECTION

WATER HARDNESS
It is advisable to contact the water supplier for information concerning the properties of the water in your
area. Good wash results are dependent also on the water hardness. For medium to very hard water,
consideration should be made to make the water softer.
Only in some cases is the use of hard water desirable, such as adding softener in the linen.
The soap supplier can help you with making the right decisions concerning hard water, soft water, washing
programs, type of soap and other related items to have the best wash results.
Characteristics
soft
medium
hard
very hard
HOT WATER
When the machine is provided with a hot water inlet, we advise connecting this inlet to a hot water supply
that is set to 70°C - 158°F. The hot water supply needs to be large enough to provide the required hot water
for the washers. Minimal temperature of hot water for the machine with electric heating 2750W must be
60°C - 140°F.
WATER CONNECTION
Most machines are made with 2 or 3 water inlets. One is always marked with „soft water". If more inlets are present,
they are marked with „Hot water" or „Hard water". Always use the flexible hose delivered with the machine,
if not present, contact your dealer. In each case do not use a fixed connection to the water supply.
For the proper function of the machine, it is necessary to keep the water pressure within the limits stated in
the technical data. It is also necessary to connect all available water inlets to a water supply. If a hard water
supply is not present, connect it with soft water. If no hot water supply is present, contact your dealer for the
proper required action.
10
INSTALLATION AND MAINTENANCE MANUAL
3AC 440V
3AC 220-240V
Fig.4.5.A. Connection of input cables
dH -
3
mmol / dm
Germany
0 - 1,25
0 - 7°
1,25 - 2,5
7 - 14°
2,5 - 3,75
14 - 21°
above 3,75
above 21°
4. Black - phase conductor
5. Black - phase conductor
fH -
France
0 - 12°
0 - 8,75°
12 - 25°
8,75 - 17,5°
25 - 37°
17,5 - 26,3°
above 37°
above 26,3°
Tab.4.5. B
3AC+N 380-415V
gr/gal
England
USA
0 - 3
3 - 7
7 - 15
above 15
516574_C_PUB_DATE_3_NOV_2009.DOC