Cable Glands And Spare Parts Kit; Cable Gland Seal Inserts - FLIR F-Series Installation Manual

Hide thumbs Also See for F-Series:
Table of Contents

Advertisement

1
F-Series Camera Installation
1.5.6
The kit contains the two 3/4" cable glands and
gland seal plugs required for non-conduit
installations.
The remaining parts included in the kit are:
1.5.7
The F-Series camera comes with two 3/4" NPT
cable glands, each with a three hole gland seal
insert. Cables may be between 0.23" to 0.29"
OD. Typically up to five cables may be needed.
Plugs are required for any insert hole(s) not
being used. The photograph at the right shows
two power cables, an Ethernet cable, a serial
control cable (no analog video is installed), and
two gland seal plugs.
If non-standard cable diameters are used, you
may need to locate or fabricate the appropriate
insert to fit the desired cable. FLIR Commercial
Systems, Inc. does not provide cable gland
inserts other than the inserts supplied with the
system.
Note
Insert the cables through the cable glands on the enclosure before terminating and connecting
them. In general, the terminated connectors will not fit through the cable gland. If a terminated cable
is required, you can make a clean and singular cut in the gland seal to install the cable into the gland
seal.
427-0030-00-12, version 170

Cable Glands and Spare Parts Kit

a spare ground wire
a spare ground nut and lock washer
two spare power terminal block plugs
two spare serial port terminal block plugs
four spare F-Series back cover screws
four spare PT-Series back cover screws

Cable Gland Seal Inserts

Ground
Lug
Serial Control
Mar 2014
Camera Power
Heater Power
Ethernet
gland seal plugs
1-5