FLIR F-Series Installation Manual page 14

Hide thumbs Also See for F-Series:
Table of Contents

Advertisement

1
F-Series Camera Installation
Camera Control Protocol: This is the communication
protocol selected for the system when operating over the
serial port. The available protocols are Pelco-D and Bosch.
Serial Communication Standard: This determines the
electrical interface selected for the user serial port. The
available settings are RS422 and RS232.
Not Used
Software Override DIP Switch: This setting determines
whether the system will use software settings for
configuration or if the dip switch settings will override the
software settings. Default is Off.
Not Used
427-0030-00-12, version 170
Table 1-2: Dip Switch Settings—SW102
Mar 2014
Settings
Description
Bit 3
Bit 4
Off
Off
Pelco-D
On
Off
NA
Off
On
Bosch
On
On
NA
Bit 5
Bit 6
Off
Off
NA
On
Off
RS422
Off
On
RS232
On
On
NA
Bit 7
Bit 8
X
X
X
X
X
X
X
X
Bit 9
Off
Software select
On
Hardware select
Bit 10
X
1-10