IBM 7012 G Series Service Manual page 248

Table of Contents

Advertisement

Error
Number
Source
408-060
K
408-080
K
409-000
K
409-008
K
409–050
K
409–051
K
409–052 T1 x
K
409–052 T2 x
K
409–053 T1 x
K
409–053 T2 x
K
409–053 T3 x
K
409–054 T1
K
409–054 T2
K
409–054 T3 x
K
409–055 T1
K
409–055 T2
K
409–056
K
409–057
K
409–058
K
409–059 T1
K
409–059 T2 x
K
409–059 T3 x
K
409–059 T4 x
K
409-080
K
409-081
K
409-082
K
D-24
Service Guide
Failing
Failure
Function
Percent
Codes
(%)
Description
B94
50
Description: Main memory Knaizuk-Hartmann test error.
B96 or
50
Action: Use MAP 0210.
B97
C63
90
Description: Multi resources full test error.
C61
10
Action: Use MAP 0210.
???
100
Description: Planar vital part FATAL ERROR.
Action: Use MAP 0210.
B94 or C64
100
Description: No 2MB available in MM. All memory banks FATAL
or D28
ERROR.
Action: Use MAP 0210.
None
None
Description: This is not an error. This code indicates a change in
configuration, that NV-RAM has been reset, etc. No parts should
be replaced for this code.
None
None
Description: This is not an error. This code indicates a change in
configuration, that NV-RAM has been reset, etc. No parts should
be replaced for this code.
Firmware
100
Description: –12 stand–by VOLT error. x is the unit number.
Firmware
100
Description: +12 stand–by VOLT error. x is the unit number.
Firmware
100
Description: 485RX protocol error (lengths). x is the unit number.
Firmware
100
Description: 485RX protocol error (time–out). x is the unit number.
Firmware
100
Description: 485RX protocol error (checksum error). x is the unit
number.
Firmware
100
Description: Marginature error (ASIC VOLT).
Firmware
100
Description: Marginature error (CPU VOLT).
Firmware
100
Description: Marginature error (+5 VOLT). x is the unit number.
Firmware
100
Description: VPD command error (read VPD).
Firmware
100
Description: VPD command error (write VPD).
Firmware
100
Description: Marginature command error.
Firmware
100
Description: Checksum logging not valid.
Firmware
100
Description: Environment over temperature.
Firmware
100
Description: I2C bus error (wrong interrupt frame).
Firmware
100
Description: I2C bus error ( unknown SIB interrupt). x is the unit
number.
Firmware
100
Description: I2C bus error ( unknown interrupt source). x is the
unit number.
Firmware
100
Description: I2C bus error ( unknown operator panel interrupt).
x is the unit number.
C59
33
Description: BUMP access to OPP or OPP access to SIF failed.
C60
33
Action: Use MAP 0210.
C88 or C89
33
C59
50
Description: BUMP access to SIF failed.
C88 or C89
50
Action: Use MAP 0210.
C59
80
Description: Operator panel cannot access the BUMP.
C60
20
Action: Use MAP 0210.
Note: This problem can be caused by an incorrectly installed CEC.