IBM 7012 G Series Service Manual page 230

Table of Contents

Advertisement

Failing
Error
Function
Number
Source
Codes
401-514
K
401-515
K
401-516
K
401-517
K
401-518
K
401-519
K
401-520
K
401-521
K
401-522
K
401-523
K
adapters
401-524
K
adapters
401-530
K
401-531
K
401-532
K
401-540
K
401-541
K
401-542
K
401-543
K
401-544
K
D-6
Service Guide
Failure
Percent
(%)
Description
C59
50
Description: Direct IO: IONIAN-SSGA.
C63
25
APR register error.
C61
25
Action: Use MAP 0210.
C59
50
Description: Direct IO: IONIAN-SSGA.
C63
25
BSR init value.
C61
25
Action: Use MAP 0210.
C59
50
Description: Direct IO: IONIAN-SSGA.
C63
25
MD0 init value.
C61
25
Action: Use MAP 0210.
C59
50
Description: Direct IO: IONIAN-SSGA.
C63
25
MD1 init value.
C61
25
Action: Use MAP 0210.
C59
50
Description: Direct IO: IONIAN-SSGA.
C63
25
XIVR6 init value.
C61
25
Action: Use MAP 0210.
C59
50
Description: Direct IO: IONIAN-SSGA.
C63
25
DSIER init value.
C61
25
Action: Use MAP 0210.
C59
100
Description: Direct IO. IONIAN register access error.
Action: Use MAP 0210.
C59
80
Description: Direct IO. SSGA POS register error.
C61
20
Action: Use MAP 0210.
C59
80
Description: Direct IO. SSGA interrupt register error.
C61
20
Action: Use MAP 0210.
C59
25
Description: Direct IO: IONIAN-SSGA. IER register error on Base
C90
25
Unit.
MCA
50
Action: Use MAP 0210.
C59
25
Description: Direct IO: IONIAN-SSGA. IER register error on Base
C90
25
Unit.
MCA
50
Action: Use MAP 0210.
C59
80
Description: Direct IO. NVRAM data lines access error.
C61
20
Action: Use MAP 0210.
C59
80
Description: Direct IO. NVRAM address lines access error.
C61
20
Walking 1 phase.
Action: Use MAP 0210.
C59
80
Description: Direct IO. NVRAM address lines access error.
C61
20
Walking 0 phase.
Action: Use MAP 0210.
C59
80
Description: Direct IO. Super IO UART1 access error.
C61
20
Action: Use MAP 0210.
C59
80
Description: Direct IO. Super IO UART2 access error.
C61
20
Action: Use MAP 0210.
C59
80
Description: Direct IO. 16550 UART access error.
C61
20
Action: Use MAP 0210.
C59
80
Description: Direct IO. Floppy disk access error.
C61
20
Action: Use MAP 0210.
C59
80
Description: Direct IO. BPP register access error.
C61
20
Action: Use MAP 0210.