Conair GasTrac User Manual page 49

Process air heater
Table of Contents

Advertisement

When there is a problem related to the
burner or ignition, the burner controller
displays a fault code and illuminates an
alarm light. To restart the GasTrac after a
burner controller alarm:
1
2
3
Alarm
LOCKOUT #16
*Flame Out Timer*
Flame did not occur
within the 4-second
flame establishing
period.
!
WARNING:
The GasTrac
should be tested
and repaired only
by qualified techni-
cians equipped
with the correct
tools and trained in
the maintenance
and repair of elec-
trical systems and
industrial gas
appliances.
UGD014/0497
Press the GasTrac
STOP
Press the burner
RESET
Press the GasTrac
RUN
Possible cause
Is the spark igniter pro-
viding a spark?
Is there a problem with
the gas supply?
Is the lens of the ultravio-
let sensor dirty?
Is negative pressure in
the building affecting sta-
tic pressure of the com-
bustion exhaust flue?
Is the burner controller
defective?
GasTrac Process Air Heater
B
C
A
button.
button.
button.
Solution
Restart the GasTrac while watch-
ing through the sight glass. If you
don't see a spark during the 4-
second ignition period:
Verify there is power supplied
to the transformer during the
ignition period.
Check the wire and connec-
tions between the transformer
and spark igniter.
Check the spark igniter.
Replace if damaged.
If the burner fails to light even
though you can see a spark:
Verify that the gas supply is
on and that the gas shutoff
valves are open during the
ignition period.
Restart the GasTrac 4 or 5
times to purge any air that may
be in the gas lines.
Verify that the gas pressure
regulator is set to supply the
correct pressure.
If the burner ignites and then
goes out, check
Clean if necessary.
Verify that the static pressure of
the combustion exhaust flue is 1
to 2 inches of water column. If
not, you may need to add a draft
fan to the flue to create the cor-
rect static pressure.
If none of the solutions above can
resolve the problem, you may
need to replace the burner con-
troller.
URNER
ONTROLLER
LARMS
the lens for dirt.
T
ROUBLESHOOTING
6-7

Advertisement

Table of Contents
loading