Specifications: Main Power Supply; Specifications: Main Power; Supply Wire - Conair GasTrac User Manual

Process air heater
Table of Contents

Advertisement

S
PECIFICATIONS
The Conair GasTrac is classified under the National Fuel Gas Code [ANSI Z233.1]
as a Category III gas appliance. An exhaust flue is required to vent the combustion
gases produced by this appliance. The purchaser is responsible for installing an
exhaust flue that meets all local, regional and national codes in the installation area.
For you safety, Conair recommends that you consult a licensed mechanical contrac-
tor who is familiar with gas flue and ducting codes in your area.
GasTrac operating characteristics
Maximum flue temperature
Minimum vent size
(single unit installation)
Vent pressure at flue collar
Installation recommendations
Provide each GasTrac with a dedicated, vertical stack that exits the
building vertically through a rain-protected roof penetration. Limit any
horizontal ducting runs to 4 feet.
Use a stainless steel, fabricated chimney flue.
Vent size should be 6 inches in diameter. If you connect multiple
GasTrac units to a stack manifold, adjust the stack size accordingly.
Static pressure at the flue collar must not exceed 1 to 2 inches water
column.
Install an induced draft fan between the GasTrac exhaust outlet and
stack ducting, if you have more than 1 to 2 inches water column pres-
sure at the flue collar while the GasTrac is operating.
S
PECIFICATIONS
The main power wire must be:
Grounded and secured with a strain relief.
Correctly sized for the current drawn.
Allowable ampacities of Copper Conductors
U.S.A.
75˚C insulation
Conductor
30˚C ambient air
Size AWG
Maximum Full Load Amps
14
15
12
20
10
30
8
43
NOTE: Local or regional electrical guidelines may have specifications that differ from the above national codes.
You should comply with the codes for your area.
UGD014/0497
: E
XHAUST
750˚F / 399˚C
CGT350: 4 in. / 10.2 cm
CGT500: 6 in. / 15 cm
CGT700: 6 in. / 15 cm
1 to 2 in. water column
:
M
P
AIN
OWER
Canada
90˚C insulation
40˚C ambient air
Ground wire
Size AWG
13
14
17
12
27
10
47
10
GasTrac Process Air Heater
F
LUE
S
W
UPPLY
European Community
70˚C insulation; 40˚C ambient air
Conductor
Maximum
2
Size mm
Full Load Amps
2,5
16
4
23
6
29
10
40
D
IRE
2-9
ESCRIPTION