Specifications: Gastrac - Conair GasTrac User Manual

Process air heater
Table of Contents

Advertisement

S
PECIFICATIONS
D
CGTHH horizontal model
Dimensions
CGT700HH Horizontal Model
CGT700HV Upright Model
CGT500HH Horizontal Model
CGT500HV Upright Model
CGT350HH Horizontal Model
CGT350HV Upright Model
Remotable GasTrac control
General
Temperature range
Maximum Flue Temperature
Combustion blower
Ignition source
Burner type
Minimum burner capacity
Maximum burner capacity
Gas consumption
Gas pressure to regulator
Gas pressure from regulator
Gas heating value
Electrical
Available voltages / Total Amps
240 V/3 phase/60 Hz
380 V/3 phase/50 Hz
415 V/3 phase/50 Hz
480 V/3 phase/60 Hz
Total Kilowatts
Emissions (all models)
Primary excess air
Oxygen (O
) [Ideal 3%-4%]
2
Carbon Dioxide (CO
)
2
Carbon Monoxide (CO)
NOX
Unburned hydrocarbons
NOTE: Elevations 3000 feet above sea level must be specified at time of purchase.
2-8
D
ESCRIPTION
: G
T
AS
H
W
H
in./cm
61/154.9
67/170.2
61/154.9
65/165.1
54/137.2
58/147.3
3.5/8.9
CGT700 models
250-350˚F / 122-177˚C
750˚F / 399˚C
1.5 Hp Peripheral
Spark igniter, interrupted
Metal-ceramic
150,000 BTU/hr
700,000 BTU/hr
230 CFH @ 250˚F/1200 CFM
675 CFH @ 350˚F/1800 CFM
4.8 A
3.0 A
2.7 A
2.4 A
1.9 kw
10% - 30%
2% - 5% acceptable range
9% - 10.5%
< 10 ppm corrected to 3% O
< 20 ppm corrected to 3% O
< 10 ppm corrected to 3% O
GasTrac Process Air Heater
RAC
D
W
CGTHV upright model
W
D
in./cm
in./cm
37/93.9
74/187.9
39/99
64/162.6
37/93.9
64/162.6
39/99
64/162.6
29/73.7
66/167.6
31/78.7
56/142.2
12.5/31.7
6/15.2
CGT500 models
250-350˚F / 122-177˚C
750˚F / 399˚C
1 Hp Peripheral
Spark igniter, interrupted
Metal-ceramic
125,000 BTU/hr
500,000 BTU/hr
150 CFH @ 250˚F/800 CFM
465 CFH @ 350˚F/1200 CFM
10 - 20 inches of water / 2.49 - 4.98 kilopascals
4 - 7 inches of water / 0.99 - 1.74 kilopascals
1000 BTU/ft
2.5 A
1.6 A
1.5 A
1.3 A
1.0 kw
2
2
2
H
D
W
Remotable
GasTrac control
Weight
Air inlet/outlet
lbs/kg
diameter in./cm
1115/505.7
12/30
1115/505.7
12/30
880/399.2
8/20.3
880/399.2
8/20.3
695/315.2
8/20.3
695/315.2
8/20.3
CGT350 models
250-350˚F / 122-177˚C
750˚F / 399˚C
1 Hp Peripheral
Spark igniter, interrupted
Metal-ceramic
90,000 BTU/hr
350,000 BTU/hr
105 CFH @ 250˚F/600 CFM
325 CFH @ 350˚F/800 CFM
3
2.0 A
1.3 A
1.2 A
1.0 A
0.8 kw
All GasTrac models meet:
UL 372, UL 795, FM, CGA,
AGA, NFPA 54, NFPA 79,
NFPA 86 and IAS
UGD014/0497
H

Advertisement

Table of Contents
loading