Replacing The Spark Igniter - Conair GasTrac User Manual

Process air heater
Table of Contents

Advertisement

R
EPLACING THE
S
I
PARK
GNITER
WARNING:
Hot surfaces
Allow the GasTrac
to cool before
removing the burn-
er guard to perform
maintenance
IMPORTANT: When
removing or inserting the
spark igniter, do not allow
the igniter electrode or
grounding rod to touch the
burner. You could damage
the burner surface.
5-4
M
AINTENANCE
The spark igniter should be replaced at least once a year to
assure trouble-free operation. You should replace the igniter
before the annual period, if you inspect it and find:
The spark gap is less than 0.125 inch. The gap should
be between 0.07 and 0.09 inch.
The igniter insulation is cracked
The spark electrodes are warped or taper to a needle-
like shape.
Do not operate the GasTrac with a worn or damaged spark
igniter. A badly burned or warped igniter can cause burner
ignition failure.
1
Stop the GasTrac.
Press the red
STOP
button, then press the
rocker switch to
OFF
2
Disconnect and lock out main power.
3
Remove the igniter wire.
Pull the wire boot, not the wire,
away from the spark igniter. If the
wire or its boot is cracked, you
should replace it.
4
Remove the spark igniter.
7
Use a
inch spark
8
plug socket and ratchet
to loosen the igniter.
Pull the igniter straight
out of the GasTrac. Do
not allow the spark
igniter to touch the
burner surface.
TIP: Before removing the spark igniter for inspection,
use a felt tip marker to mark the position of the igniter
in its threaded hole. By
indexing the position,
you will able to return
the igniter to the correct
position after inspection.
The igniter must be
installed so that the
ground rod is 180˚
away from the
burner surface.
GasTrac Process Air Heater
2216
235.0
OP1
OP2
250.0
SP2
REM
RUN
MAN
HOLD
.
3
4
UGD014/0497

Advertisement

Table of Contents
loading

Table of Contents