CAUTION:
Always disconnect and lock out the main
power sources before making electrical
connections. Electrical connections should
be made only by qualified personnel.
1
Open the GasTrac electrical enclosure.
Turn the disconnect dial on the GasTrac's door
to the Off position. Turn the captive screw, and
swing the door open.
2
Insert the main power wire
the electrical enclosure. Secure the wire with a rubber
compression fitting or strain relief.
3
Connect the power wires
at the top of the disconnect holder.
4
Connect the ground wire
point shown in the diagram.
IMPORTANT:
the wiring diagrams that came with
the GasTrac for the most accurate
information about electrical com-
ponents and connections.
The RTD probe monitors the temperature of the drying air as
it enters the hopper. If the probe is not installed correctly, tem-
perature readings will be inaccurate.
1
Insert the probe in the
delivery air inlet
hopper. The end of the probe
must not touch the walls of
the inlet pipe. Most hoppers
provide a hole that is compat-
ible with the probe's
NPT compression fitting.
2
Plug the probe's cable
into the GasTrac control
box. Coil any excess cable and
secure with a wire tie.
UGD014/0497
Electrical hazard.
through the knockout in
to the three terminals
to either grounding
Always refer to
of the
1
/
-inch
8
GasTrac Process Air Heater
C
ONNECTING
M
AIN
O
Honeywell
ESC SEL
I
NSTALLING THE
RTD P
P
OWER
ROBE
3-7
I
NSTALLATION