HAMPTON BAY HI300 Owners & Installation Manual
HAMPTON BAY HI300 Owners & Installation Manual

HAMPTON BAY HI300 Owners & Installation Manual

Wood cast insert

Advertisement

Wood Cast Insert
Tested by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
919-544b
MODEL:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.hampton-ire.com
French Manual: http://ow.ly/ZvwLL
Manuel en Français: http://ow.ly/ZvwLL
HI300
Owners &
Installation Manual
12.15.16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HI300 and is the answer not in the manual?

Questions and answers

Summary of Contents for HAMPTON BAY HI300

  • Page 1 Installation Manual www.hampton-ire.com French Manual: http://ow.ly/ZvwLL Manuel en Français: http://ow.ly/ZvwLL MODEL: HI300 Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 919-544b 12.15.16...
  • Page 2 The following statements are required by the Environmental Protection Agency: “This manual describes the installation and operation of the Regency HI300 wood heater. This heater meets the 2015 U.S.Environmental Protection Agency’s crib wood emission limits for wood heaters. Under speciic test conditions this heater has been shown to deliver heat at rates ranging from 12,000 BTU/hr. to 36,800 BTU/hr.”...
  • Page 3: Table Of Contents

    SAFETY LABEL OPERATING INSTRUCTIONS Seasoned Firewood.............23 Safety Guidelines ............24 Safety Label For Hi300 ..........4 First Fire ..............24 Creosote ..............25 UNIT DIMENSIONS Ash Disposal..............25 Fan Operation .............25 Wood Storage ..............25 with standard ..............5 Door Gasket ..............26 Cast faceplate..............5 Glass Cleaning ............26...
  • Page 4: Safety Label For Hi300

    OF APPLIANCE. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE. MODEL: HI300 DO NOT REMOVE BRICKS OR MORT AR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE TESTED TO: ULC S628- 93 / UL 1482 FIRE.
  • Page 5: With Standard

    WITH STANDARD CAST FACEPLATE NOTE: Before assembling your Insert, use these dimensions to ensure appropriate clearances will be met (refer to Masonry and Fac- tory Built Fireplace Clearances section). Hampton HI300 Wood Cast Insert...
  • Page 6: With Oversize

    WITH OVERSIZE NOTE: CAST FACEPLATE Before assembling your Insert, use these dimensions to ensure appro- priate clearances will be met (refer to Masonry and Factory Built Fireplace Clearances section). Hampton HI300 Wood Cast Insert...
  • Page 7: Installation

    Emissions from burning wood or gas could to install the chimney liner. contain chemicals known to the State of Cali- fornia to cause cancer, birth defects or other reproductive harm. Hampton HI300 Wood Cast Insert...
  • Page 8: Masonry And Factory Built Fireplace Clearances

    Compare proposed system R of 1.231 to R = 1/k x T = 1/0.84 x .75 = 0.893. speciied R of 0.893. Since proposed system R is greater than required, the system is Thermal Resistance: acceptable. )(hr)( F) = )(K) Hampton HI300 Wood Cast Insert...
  • Page 9: Installing Your Insert

    Be sure to leave the unit out at least 3 to 4 inches in order to make the necessary lue connections and to install the faceplate. Be sure to protect your hearth extension during the installation, ie. with a heavy blanket. Hampton HI300 Wood Cast Insert...
  • Page 10: Installation Into Amasonry Fireplace

    The greater draft can decrease problems such as, diicult start-ups, smoking out the door, and dirty glass. 10 | Hampton HI300 Wood Cast Insert...
  • Page 11: Stainless Steel Smoke Delector Adjustment / Replacement

    WARNING: Operation of the unit with out proper installation of smoke delector will void warranty. Ensure defector is seated so bolts are situated at the top of the keyhole before tightening. Hand tighten bolts only. Hampton HI300 Wood Cast Insert...
  • Page 12: Standard Cast Faceplate Installation

    Mantel Top. If there is a gap present you will need to lower that side cast by loosening 2 bolts, see step 6 for bolt location (check to see if level). 12 | Hampton HI300 Wood Cast Insert...
  • Page 13 Carefully slide the Mantel Top back into position. Slide Mantel Top back. Cast Cast adjustment mounting bolts bolts for height adustment. See Step 3 to identify side casts. See next page for recommended measurements. Hampton HI300 Wood Cast Insert...
  • Page 14 Important: Verify gap between cast and door did not change when rear adjustments have been made. Carefully open door slowly, to ensure that the door does not rub against cast sides. These are just recommended measurements. 14 | Hampton HI300 Wood Cast Insert...
  • Page 15: Oversize Cast Faceplate Installation

    Mantel Top Spacer and the underside cast of the Mantel Top. If there is a gap present you will need to lower that side cast by loosening 2 bolts, see side cast adjustment section for bolt location (check to see if level). Hampton HI300 Wood Cast Insert...
  • Page 16 11) The unit may now carefully be slid into fi nal position. See side cast adjustments if faceplate needs aligning. Right Side Face- Left Side Faceplate plate Backside of Unit & Faceplate Shown. 16 | Hampton HI300 Wood Cast Insert...
  • Page 17 Important: Verify gap between cast and door did not change when rear adjustments have been made. Carefully open door slowly, to ensure that the door does not rub against cast sides. These are just recommended measurements. Hampton HI300 Wood Cast Insert...
  • Page 18: Cast Grill Installation

    5. Lift the bottom of the glass upwards till it stops, secure glass retainer using the 8 bolts. Do not wrench down on the bolts, as this may cause the glass to break. 18 | Hampton HI300 Wood Cast Insert...
  • Page 19: Fan Installation

    Switch Plate. Neutral Green Manual/ Live Ground Auto 120V AC Switch Switch 60 Hz Fan Thermodisc (normally open) Black Black Black Ground Ashlip Blower/Fan Wiring Diagram Draft Control Support Clips Switch Plate Hampton HI300 Wood Cast Insert...
  • Page 20: Power Outlet Conversion

    8) Attach the green ground wire with the #8 x 3/8" Pan other side. Head Phillips steel self tapping screw, previously removed from the left side. 20 | Hampton HI300 Wood Cast Insert...
  • Page 21 12) Attach the fan defl ector to the main fan body by replacing the Phillips screw on the top of the fan housing. Thermodisc Assembly Template (If required) Location of New Thermdisc Holes Thermodisc As- sembly Base Location of Old Thermdisc Holes Diagram 1 Hampton HI300 Wood Cast Insert...
  • Page 22: Firebrick Assembly

    Install the air tube into the holes in the side channels. The notch goes on the right hand side with the air holes facing toward the door. Slide the tube into the left Front View 22 | Hampton HI300 Wood Cast Insert...
  • Page 23: Seasoned Firewood

    Two dry pieces banged together sound hollow; wet pieces sound solid and dull. • Dry wood weighs much less than wet wood. • Split a piece of wood. If the exposed surface feels damp, the wood is too wet to burn. Hampton HI300 Wood Cast Insert...
  • Page 24: Operating Instructions

    15) Do not operate the unit if the glass is broken or missing. Do not operate the unit if the gasket- ing is worn out and not sealing the door or the glass. How to Light & Maintain a Wood Stove Fire 24 | Hampton HI300 Wood Cast Insert...
  • Page 25: Creosote

    (3mm / 1/8" or more) it should be removed to reduce the risk of a chimney ire. Hampton HI300 Wood Cast Insert...
  • Page 26: Door Gasket

    Right Hand Cast Side. If tight or rubbing, loosen the 7/16 nuts and adjust the clearance and then re-tighten. Cleaning & Maintaining Your Wood Stove 26 | Hampton HI300 Wood Cast Insert...
  • Page 27: Latch Adjustment

    4) Re-secure Latch to Mounting Bracket using 2 bolts. Latch Assembly re-assembled with spacers removed. Mounting Latch Bracket 5) Re-secure the Latch Assembly to the unit using 2 bolts. Cleaning & Maintaining Your Wood Stove Hampton HI300 Wood Cast Insert...
  • Page 28 Check glass for cracks Replace if required. Clean blower motor Disconnect power supply. Remove and clean blower. *DO NOT LUBRICATE* Inspect and clean chimney Annual professional chimney cleaning recommended. Cleaning & Maintaining Your Wood Stove 28 | Hampton HI300 Wood Cast Insert...
  • Page 29: Main Assembly

    20) 300-571* Door Assembly 948-155 Bottom Door Hinge Pin 21) 948-179 Wooden Handle Black * Last digit of part number represents color: 948-178 Wooden Handle Dark Brown 1 = Metallic Black, 5 = Timberline Brown, Hampton HI300 Wood Cast Insert...
  • Page 30: Standard Cast Faceplate

    300-921 Cast Faceplate - Metallic Black 300-925 Cast Faceplate - Timberline Brown 200) * Top Faceplate 201) * Left Side Faceplate 202) * Right Side Faceplate * Not available as a replacement part. 30 | Hampton HI300 Wood Cast Insert...
  • Page 31: Oversize Cast Faceplate

    301) * Left Side Faceplate 302) * Right Side Faceplate 303) 300-060 Mounting Plate LH 305) 300-061 Mounting Plate RH Not Shown in the Drawing 300-005 Top Retainer * Not available as a replacement part. Hampton HI300 Wood Cast Insert...
  • Page 32: Brick Panels

    BRICK PANELS Part # Description 180-960 Brick Set - Complete 32 | Hampton HI300 Wood Cast Insert...
  • Page 33 Hampton HI300 Wood Cast Insert...
  • Page 34 At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty. 34 | Hampton HI300 Wood Cast Insert...
  • Page 35: Warranty

    Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Hampton HI300 Wood Cast Insert...
  • Page 36 Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx within ninety (90) days of purchase. 36 | Hampton HI300 Wood Cast Insert...
  • Page 37 For fireplace care and tips and answers to most common questions please visit our Customer Care section on our Web Site. Please feel free to contact your selling dealer if you have any questions about your Regency product. Hampton HI300 Wood Cast Insert...
  • Page 40 Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Hampton is a trademark of FPI Fireplace Products International Ltd. Printed in Canada © FPI Fireplace Products International Ltd. 2016...

Table of Contents