AeGIS 4000 QUICK REFERENCE GUIDE
Log into programming mode
1. Press # and 0 simultaneously, screen will stop scrolling. Repeat this step if screen is still scrolling.
2. Enter the 4-digit master code (default master code is 0000).
3. Select the function code from the table below.
Function Code
Exit the programming or hang-up the call.
*
#
Save program or inniate a call.
Turn power off then press and hold these keys,
and #
*
turn the power on.
00
Change system master code
DEFAULT MASTER CODE=0000
01-20
Individual access code for relay #1
Maximum 20 codes
21-40
Individual access code for relay #2
Maximum 20 codes
41-50
Individual access code for relay #1 & #2
Maximum 10 codes
51
Relay #1 open time interval (01-90 sec)
DEFAULT= 12 SECONDS
52
Relay #2 open time interval (01-90 sec)
DEFAULT= 12 SECONDS
60
Delete all access codes 01-20
61
Delete all access codes 21-40
62
Delete all access codes 41-50
65
Delete all access codes
70
Direct call forwarding phone number up to 11-
digit. Intercom mode is Off.
71-72
Auto or manual call forwarding phone
number up to 11-digit. Must be enabled.
1. To place a call from the AeGIS 4000: Press #.
2. To grant access to a visitor: Press 9 (door 1) or
Press 8 (door 2).
3. To use a personal access code: Press * then release,
and press 4-digit access code.
4. To extend a talk time: tenant must press # after hearing
the time-out warning beep.
5. To enable call forwarding:
Local press 0 and * simultaneously then release then
select 71(call forwarding on 71) or 72 (call forwarding on
72) then press #.
Premise phone lift the handset wait for dial tone then
press ## then select 71(call forwarding on 71) or 72 (call
forwarding on 72) then press #.
Remote phone lift the handset wait for dial tone then
press # and4-digit master code then select 1(call forwarding on
71) or 2 (call forwarding on 72) then press #.
6. To open and Closed, to open and hold open and then
closed door 1 or door 2, see table on the right
Description
SYSTEM OPERATION
Function Code
76
Delete phone number on 70, 71 and 72
87
Disable or Enable automatic call
forwarding. 0=disabled 1=enabled
DEFAULT= DISABLED
88
Select automatic call forwarding phone number
on 71 or 72.
89
Select automatic call forwarding time or hang-
up time (15-90 seconds)
DEFAULT= 15 SECONDS
90
Manual closed or open door #1
1= open 0= closed
91
Manual closed or open door #2
1= open 0= closed
92
Talk time (10-90 seconds)
DEFAULT=60 SECONDS
93
Lock-out count (03-09)
DEFAULT=3 TRIES
94
Auxiliary Mode, 0=disabled, 1=enabled control
by door open interval 2=enabled control by AUX
DEFAULT= 0 (disabled)
95
Alarm mode
DEFAULT= 10 Sec (local) 30 Sec (remote)
96
System answer mode (0= disabled,
1,2,3,...9 = enabled)
DEFAULT=DISABLED
97
Do not disturb mode (0= disabled 1= enabled)
DEFAULT=DISABLED
98
Select initiating premise call key
0= #
DEFAULT=#
99
Set memory to factory default.
LOCAL
PREMISE PHONE
1.Press 0 and #
• Press ##, you will
simultaneously then
hear "One short
release
beep".
2. Enter 4-digit
• Press
master code then #
For Door 1
3. PRESS
9 to open and closed
90 (door 1) or
8 to open and hold
91 (door 2), then #
open
you will hear "one
7 to closed
short beep"
4. PRESS 1THEN #
For Door 2
TO OPEN or
5 to open and closed
PRESS 0 THEN #
4 to open and hold
TO CLOSED.
open
3 to lock
Description
1= *
REMOTE PHONE
• Call the system, you
will hear "One short
beep".
• Press # then the 4-
digit master code.
• Press
For Door 1
9 to open and closed
8 to open and hold
open
7 to closed
For Door 2
5 to open and closed
4 to open and hold
open
3 to lock