Illustration 3.11: AC Cable Wire Strip
Legend
1 Blue cable - Neutral
2 Yellow/green cable - Earth
The illustration shows the stripping of insulation of all 5 wires of the AC cable. The length of the
PE wire must be longer than the mains and neutral wires.
Illustration 3.12: AC Connection Area
1.
Verify the inverter matches the grid-voltage.
2.
Release main circuit breaker and make precautions to prevent reconnection.
3.
Open the front cover.
4.
Insert the cable through the AC gland to the terminal blocks.
5.
The three mains wires (L1, L2, L3) and the Neutral wire (N) are mandatory and must
be connected to the 4-pole terminal block with the respective markings.
6.
The Protective Earth wire (PE) is mandatory and must be connected directly to the
chassis PE terminal. Insert the wire and fasten the screw to secure the wire.
L00410309-07_02