Table 53.
Technical data
DHP-AL
Type
Refrigerant
Compressor
Electrical data
3-N ~50Hz
Electrical data
1-N ~50Hz
10
Performance
8
Nominal flow
External available
pressure
9
Lowest outdoor
temperature for
compressor start
Max/Min tempera-
ture
Pressure switches
80 – Service instructions VMGFC302
Type
Amount
kg
Test pressurisation
MPa
Design pressure
MPa
Type
Oil
Mains power supply V
Rated output, com-
kW
pressor
Rated output,
kW
circ.pumps/fan
Auxiliary heater, 5
kW
step
16
A
Start current
Fuse
A
Mains power supply V
Rated output, com-
kW
pressor
Rated output,
kW
circ.pumps/fan
Auxiliary heater, 3
kW
step
A
Start current
16
Fuse
A
kW
1
Heat factor
COP
1
kW
2
Heat factor
COP
2
2
kW
Incoming power
Cooling circuit
l/s
Heating circuit
l/s
Cooling circuit
kPa
Heating circuit
kPa
°C
Cooling circuit
°C
Heating circuit
°C
Low pressure
MPa
Operation
MPa
High pressure
Mpa
6
8
0,95
1,45
3,0
3,2
0,4
0,6
12
10
3
4
5
6
3
4
10
/16
/20
/20
16
/16
/20
/
/
25
7
/25
14
/30
15
25
7
/25
14
/30
3,2
3,6
0,4
0,6
11
21
3
4
5
3
4
25
/32
/40
25
/32
/40
5,00
7,02
2,85
3,10
5,90
7,96
3,26
3,45
1,8
2,3
0,32
0,49
0,14
0,20
46
83
45
43
10
12
Air/water
R404A
1,50
1,60
3,4
3,1
Scroll
POE
400
4,2
5,0
0,6
0,7
3/6/9/12/15
18
17
5
6
3
4
5
6
/20
16
/16
/20
/20
16
/
25
15
25
7
/30
14
/35
15
230
4,5
5,5
0,6
0,7
1,5/3,0/4,5
26
28
5
3
4
5
32
/40
/50
32
8,20
9,84
2,85
3,00
9,85
11,3
3,29
3,35
3,0
3,4
0,58
0,64
0,24
0,28
69
95
40
51
-20
20/-25
55/20
0,08
2,65/2,85
3,10
3
4
5
6
/20
/25
/25
/
7
14
15
/30
/35
3
4
5
/40
/50

Hide quick links: