AIR
CONDITIONER
TroubleOiagnosesandCorrecrionr
TROUBLE DIAGNOSES
AND
CQRRECTIONS
AIR CONDITIONER
DIAGNOSES
Insufficient
cooling
Bubbles
in
sight glass
Check
refrigeration
line for
gas
leaks
and
repair
leaks
if any
Charge
reo
frigerant
to correct
level
In
case
of
too many leaks
stop
compressor
dig
charge
the
system
evacuate and
recharge
the
system
As necessary
replace
receiver drier
Air
in
system
may
cause
bubbles
in
sight glass
System pressure
and temperature of
discharge
air
are
abnormal
Refer
to
Performance Test
Diagnoses
for
detail
Suction pressure
is
high
Discharge
pressure is
high
Expansion
valve
is open
exces
sively
Replace
expan
sian valve
Overcharge
of
refrigerant
Discharge
some
refrigerant
to correct
level
Air is
mixed
in
Discharge
sys
tern
and
replace
drier
Evacuate and
recharge
system
Condenser
s
fin
is
dented
or
clogged
with dust
Clean
exterior
surface with
water
Suction pressure
is
low
Suction pressure
is
high
while
discharge
pres
sure
is low
Valve
or
gasket
of
compressor is
damaged
Repair
or
replace
compressor
Pipe
at receiver
drier outlet has
low
temperature
Receiver drier
is restricted
Replace
receiver
drier
Fin
and
tllbe of evaporator
have
some
dents
Replace
or
repair
evaporator
No bubbles
in
sight glass
With
manifold
gauge
check system
pressures
Measure temperature of
discharge
air
Refer
to
Performance
Test
Temperature
of
discharge
air is ab
normal but
system
pressure is
normal
Check
air
flow system
Check grommets
on
car s
dash
panel
for
air
leaks check
other seals
of
car
Expansion
valve
is
close
excessively
or
gas
leakage
from thermo bulb
Replace
expansion
valve
HA 39