9.2

BACKLIGHT FOR LCD

• The backlight of the LCD can be set to:
1. Be on all the time
2. Be on only when a weight is placed on the scale
3. Turned off
• To set the backlight press and hold [Pst] key for 4 seconds.
• The weight display will show "EL xx" where xx is the current
setting for the backlight.
• Press [U. Wt./Units] to scroll through the options.
EL on
"
EL Au
"
EL OFF
"
• Press the [Tare] key to store the value or press the [Zero]
key to escape from this setting and return to weighing.

10.0 ERROR CODES

During the initial power-on testing or during operation, the scale may
show an error message.
described below.
If an error message is shown, repeat the step that caused the message,
turning the balance on, carry out the calibration or other functions. If the
error message is still shown contact your dealer for further support.
ERROR CODE
Err 1
Err 2
Err 4
Err 6
© Adam Equipment Company 2007
Sets the backlight to be on at all times.
"
Sets the backlight to operate automatically when a weight is
"
placed on the scale or a key is pressed.
Sets the backlight to be off.
"
The meaning of the error messages is
DESCRIPTION
Time input error.
Date input error
Initial Zero is greater than
allowed (typically 4% of
the maximum capacity)
when power is turned on
or when the [Zero] key is
pressed,
A/D count is not correct
when turning the scale
on.
POSSIBLE CAUSES
Tried to set an illegal time, i.e.
26hours
Tried to set an illegal date, i.e. 36
day
Weight is on the pan when turning
the scale on.
Excessive weight on the pan when
zeroing the scale.
Improper calibration of the scale.
Damaged load cell.
Damaged Electronics.
Platform is not installed.
Damaged load-cell.
Damaged electronics.
17