[703] - Delay Between Dialing Attempts
For standard (force) dialing, the panel will go off-hook,
search for dial tone for 5 seconds, hang-up for 20 seconds,
go off-hook, search for dial tone for 5 seconds, then dial. If
there is no initial handshake recognized within 40 sec-
onds, the panel will hang up. This programmable timer
adds a delay before the next call is attempted, and is
defaulted to 001 for a total of six seconds.
5.10 Module Programming PWS Sect 10
The programming sections listed below pertain to additional
modules on the system. For instructions on programming
these modules and a description of each programming sec-
tion, see the associated Installation Manual s.
1. PC5400 Programming Section [801]
2. PC5936 Programming Section [802]
• PC5936 audio interface will allow you to connect 7 (with
the PC4937 Audio Expansion Module 15) Interior
(PC5921) or exterior (PC5921EXT) Intercom Station.
These surface mounted stations contain a speaker and a
microphone. This module enables Page/Answer, Do
Not Disturb, Baby Monitor, Answer Incoming Calls,
Doorbell Function, and Background Music features in
your alarm. This module also has the Listen-in feature
for central station monitoring. The central station can
select the audio station, listen/talk, extend on-line time
and hang up. The Listen-In feature can be enabled sepa-
rately for telephone numbers 1/3 and 2.
and/or video sessions will be disconnected if the panel
needs to communicate alarms to the central station.
• Alternate Communicator Programming Section [803]
• PC5132 Programming Section [804]
• PC5100 Programming Section [805]
• PC5108L Programming Section [806]
NOTE:
All Talk/Listen and/or video sessions are disconnected
when the panel communicates alarms to the central station.
• T-Link Programming Section [851]
NOTE:
Option [5] in Section [382] must be enabled to access
this section.
The T-Link module can be used to communicate panel
events in SIA format over a Local Area Network (LAN). It
can also be used for downloading (this requires DLS2002
or higher).
Telephone 1 & 3 Listen-In Enabled . . . . . . . Section [381], Option 5
Telephone 2 Listen-In Enabled . . . . . . . . . . Section [381], Option 6
Periodic Camera Test
When the Periodic Camera Test
Periodic Camera Test option is enabled, the
Periodic Camera Test
Periodic Camera Test
panel will test cameras connected to a PC5108L module
every 30 minutes. Only cameras with the Camera Test
option enabled will be tested. See your PC5108L Installa-
tion Manual for more information on camera tests.
If the Local Mode
Local Mode
Local Mode option is ON, the panel will send events
Local Mode
to the PC5108L module, Downlook will not be initiated if
requested. If the Local Mode option is OFF, the panel will
send communicated events to the PC5108L module.
Downlook will initiate when requested. See your
PC5108L Installation Manual for more information.See
Periodic Camera Test Section [017], Option [7] and Local
Mode Enabled/Disabled Section [381], Option [8]
5.11 Special Installer Instructions PWS Sect 11
[901] - Installer Walk Test Mode Enable / Disable
The Installer Walk Test
Installer Walk Test can be used to test the alarm state of
Installer Walk Test
Installer Walk Test
each zone of the panel. The Walk Test cannot be used to test
zone type [24]. Before beginning the Walk Test, ensure the
following conditions are met:
1. The panel is disarmed
All Talk/Listen
WWW.DIYALARMFORUM.COM
2. The Keypad Blanking option is disabled (section [016]: [3])
3. The Fire Bell is Continuous option is disabled (section
[014]: [8])
4. The Transmission Delay is disabled, if Transmission Delay is
not required (section [377])
NOTE:
Fire Troubles are not supported in Walk Test. All out-
puts will activate for all partitions during the Walk Test,
regardless of programming.
To perform a Walk Test, do the following:
1. Enter Installer Programming
2. Enter Section [901]
When any zone is violated the panel will activate the Bell
Output for two seconds and log the event to the event
buffer. Check the event buffer to ensure that all zones and
FAP keys are functioning properly.
NOTE:
If there is no zone activity on the system for 15 min-
utes, the system will end the Walk Test and return to the
normal state.
To stop the test, you must do the following:
1. Enter Installer Programming
2. Enter Section [901]
Zones do not have to be restored to stop the test. After the
test is complete, check the event buffer to ensure that the
Audible/Silent 24-Hr. PGM alarms have been restored.
NOTE:
The Alarm Memory is cleared upon entering Walk
Test mode. When the Walk Test is complete, the Alarm Mem-
ory will indicate the zones tested. The Alarm Memory will be
cleared the next time the panel is armed.
NOTE:
While the Walk Test is in progress, all three LEDs
(Ready, Arm, Trouble) will flash at a rapid rate. At the start of
the Walk Test, a TS signal will be communicated. When the
test is stopped a TE (test end) is communicated.
[902] - Reset Module Supervision
All modules will automatically enroll within one minute
upon power up (except the PC5132 if there are no serial
numbers programmed). If modules are to be removed, this
section should be entered after the removal of the modules
so that it can clear any supervisory Troubles that may be
present. When this mode is entered, the system will re-eval-
uate the components of the system.
NOTE:
It may take up to a minute to enroll or delete a mod-
ule. Before entering Section [903] to view the module field,
this time should be taken into account.
If there is a module that is not properly communicating
with the system and this section is entered, the module
will be deleted from the system.
Once executed, all pending Supervisory Trouble Restorals
will not be logged or transmitted.
44