[015] - THIRD SYSTEM OPTION CODES
Option
Definition
1
[F] Key
2
[P] Key Annuncia-
tion
3
Quick Exit
4
Quick Arming/Func-
tion Key
5
Bypass Access Code
6
Master Code
P r o g r a m m i n g S e c t i o n s : 5 . 3 B a s i c P r o g r a m m i n g P W S S e c t 3
On/Off
Description
ON
Bell Squawk During Auto-arm Enabled. The bell output will sound a single squawk every 10 sec-
onds during the Auto-arm Pre-alert time. This will inform anyone on the premises that the system is
being armed.
OFF
Bell Squawk During Auto-arm Disabled. The bell output will not be activated during the Auto-
arm warning time
ON
Bell Squawk On Exit Delay. The bell output will squawk once per second during the Exit Delay
time. The bell will also sound 3 squawks per second for the final 10 seconds
NOTE: If the panel is armed using the Stay function key, or by entering [*] [9] [Access
Code], there will be no bell squawks during entry and Exit Delays, except for the arm/dis-
arm bell squawks.
OFF
No Bell Squawk On Exit Delay.
NOTE: This audible option does not apply to Stay and No Entry arming modes.
ON
NOTE: Bell Squawk On Entry Delay. The bell output will pulse with the same timing as the buzzer
during the Entry Delay time. The bell will also sound 3 squawks per second for the final 10 seconds if
Option 6 in this section is enabled.
OFF
No Bell Squawk On Entry Delay
ON
Bell Squawks on Trouble. When there is a Trouble condition annunciated on the system keypads,
the bell will squawk 2 times every 10 seconds (as per the keypad buzzer). The bell will be silenced
when the keypad beeps are silenced (any key pressed on keypad).
NOTE: This feature must not be used with 2 partitions.
OFF
No Bell Squawks on Trouble.
ON
Audible Exit With Urgency. The keypad will sound a pulsing tone (once per second) during the Exit
Delay. For the last 10 seconds of the Exit Delay, the keypad and bell / siren (if enabled) will sound a
different tone (3 tones per second) to warn that the Exit Delay is about to expire.
OFF
Silent Exit Delay. The keypad will not sound during the Exit Delay.
ON
Exit Delay Termination Enabled. The Exit Delay will be terminated once a Delay 1 Zone for the
entry/exit door or area is restored. All audible options associated with the Exit Delay will be silenced
when the Exit Delay is terminated. Force-armable Delay 1 type zones will also terminate the Exit
Delay.
OFF
Exit Delay Termination Disabled. The Exit Delay timer will continue to count even after the Delay
Zone for the entry/exit door or area is restored. All audible options associated with the Exit Delay will
function until the time programmed for the Exit Delay has elapsed.
ON
Fire Bell is Continuous. The bell output will sound for all Fire type alarms until an access code is
entered to silence the alarm or disarm the system regardless of the time programmed for bell Time-
out in Section [005].
OFF
Fire Bell Follows Time-out. The bell output will sound for all Fire type alarms for the duration of
Bell Time-out or until an access code is entered.
On/Off
Description
ON
[F] Key Enabled. Pressing and holding the [F] key for 2 seconds will generate a Fire alarm. The key-
pad will sound a set of 3 beeps to acknowledge the valid alarm and the bell or siren will pulse one
second on, one second off if option 8 of Section [013] is disabled (Standard Fire option). If Fire Bell
is Continuous (Section [14], Option 8) is selected the alarm output will sound until a code is
entered; otherwise it will sound until a code is entered or the alarm output times out.The Fire, Auxil-
iary, Panic keys will operate even if Keypad Blanking and Keypad Lockout are active (see Section 5.3
'Basic Programming PWS Sect 3' [012]).
OFF
[F] Key Disabled. The [F] key will not sound or report an alarm when pressed.
ON
[P] Key Audible. When a valid [P] key alarm is generated, the keypad buzzer will sound a series of 3
beeps to acknowledge the alarm. The bell or siren will also sound for the length of Bell Time-out.
NOTE: The Fire, Auxiliary, Panic keys will operate even if Keypad Blanking and Keypad
Lockout are active (See Section 5.3 'Basic Programming PWS Sect 3' [012]).
OFF
[P] Key Silent. When a valid [P] key alarm is generated: the Keypad buzzer and the bell output will
remain silent; the alarm transmission will still be transmitted if programmed.
ON
Quick Exit Enabled. When the system is armed, users may enter the [*][0] command to allow a sin-
gle Delay 1 or Delay 2 Zone to be activated so they may leave the premises. Only one Delay zone may
be activated. Additional activity on another Delay zone will initiate its respective alarm sequence. If
the Delay zone is still open two minutes after the [*][0] command is entered, the Entry Delay will be
initiated. If armed in the Stay mode, the automatic bypass on Stay/Away zones will not be removed.
OFF
Quick Exit Disabled.
ON
Quick Arming Enabled/Function Keys Do Not Require Code. [*][0] arming and Stay/Away func-
tion keys may be used to arm the system without the entry of a valid access code. All other function
keys may also be used without the entry of an access code.
OFF
Quick Arming Disabled/Function Keys Require Code. [*][0] arming is not permitted, and all
function keys require the entry of an access code to activate (including Stay/Away keys).
NOTE: This option must be on if less than version 3.00 of the PC5132 is used.
ON
Access Code Required to Bypass Zones. After entering the [*][1] Bypass Zones command, an
access code must be entered before zones may be bypassed.
OFF
Access Code Not Required to Bypass Zones. Enter the [*][1] Bypass Zones Command to bypass
zones. Note: This option is supplemental to Option 4.
ON
Master Code Not User Changeable. The Master Code (Access Code 40) may not be changed by
the user, and may only be programmed in the Installers Programming mode.
OFF
Master Code User-Changeable. The Master Code (#40) may be programmed by the user using the
[*] [5] [Master Code] command. The Master Code may also be programmed in the Installer Program-
ming mode.