Function Keys - DSC Power832PC5010 CP-01 Installation Manual

Table of Contents

Advertisement

[*] [0] Quick Arm
If the Quick Arm Enable
Quick Arm Enable option is enabled the panel can
Quick Arm Enable
Quick Arm Enable
be armed by entering [*][0]. This is a useful method of
arming a partition when someone without an access code
will be required to arm a partition.
[*] [0]
Quick Exit
Quick Exit will allow someone to leave an armed premise
through a Delay type zone without having to disarm and
rearm the system.
When [*][0] is entered, if the Quick Exit Enabled option is
enabled, the panel will provide a 2-minute window to
exit. During this time the panel will ignore the first activa-
tion of a Delay type zone. When the Delay zone is secured
the panel will end the 2-minute time period.
If a second Delay zone is tripped, or if the zone is not
restored after two minutes, the panel will start entry
delay.
NOTE:
If Quick Exit is used on a partitioned system, Keypad
Blanking and Access Code Required to Remove Blanking
should be enabled.
Quick Arm Enable. . . . . . . . . . . . . . . . . . . Section [015], Option [4]
Quick Exit Enable . . . . . . . . . . . . . . . . . . . Section [015], Option [3]

4.3 Function Keys

There are five function keys on the PC5010 CP-01 key-
pads labelled Stay, Away, Chime, Reset and Exit. The
operation of these keys is described below. The function is
activated by pressing and holding the key for 2 seconds.
'Stay' - Stay Arm
Arms the partition to which the keypad is assigned. All
Stay/Away type zones will be automatically bypassed.
Delay type zones will provide entry and Exit Delay. The
Quick Arm feature must be enabled for this key to func-
tion (Section [015], Option [4]) . If Quick Arming is not
enabled, the user must enter their access code after press-
ing the function key in order to arm the system in the Stay
mode.
'Away' - Away Arm
Arms the partition to which the keypad is assigned. All
Stay/Away type zones will be active at the end of the Exit
Delay. Delay type zones will provide entry and Exit
Delay. The Quick Arm feature must be enabled for this
key to function (Section [015], option [4]) . If Quick Arm-
ing is not enabled, the user must enter their access code
after pressing the function key in order to arm the system
in the Away mode.
'Chime' - Door Chime On/Off
Pressing the key will toggle the Door Chime feature ON
or OFF. One solid beep means the feature has been dis-
abled, three short beeps means it has been enabled.
'Reset' - Reset Smoke Detectors
Pressing this key will cause the panel to activate for 5 sec-
onds any output programmed as Sensor Reset. ( see sec-
tion '[*] [7] Command Output Functions' ).
'Exit' - Activate Quick Exit
Pressing this key will cause the panel to activate the Quick
Exit feature ( see section '[*] [0] Quick Exit' ).
Function Key Options
The programming of any function key on any keypad
may be changed to one of the options listed below (see
section 2.7 'Keypad Assignment' for instructions on
changing function key programming.)
[00] - Null Key
The key is not used and will perform no function when
pressed.
WWW.DIYALARMFORUM.COM
K e y p a d C o m m a n d s : 4 . 3 F u n c t i o n K e y s
[01] - Select Partition 1
Provides an easy way to select partition 1. This is the
same as pressing and holding the [#] key then pressing
and holding the [1] key to select partition 1 ( see section
'Global and Partition Keypad Operation' ) .
[02] - Select Partition 2
Provides an easy way to select partition 2. This is the
same as pressing and holding the [#] key then pressing
and holding the [2] key to select partition 2 ( see section
'Global and Partition Keypad Operation' ) .
[03] - Stay Arm
Same as described in Function Keys - Section 3.5.
[04] - Away Arm
Same as described in Function Keys - Section 3.5.
[05] - [*]+[9] No Entry Delay Arm
After this function key is pressed the user must enter a
valid access code. The partition will arm and remove entry
delay from the partition when the Exit Delay expires ( see
section '[*] [9] Arming Without Entry Delay' ) .
[06] - [*]+[4] Door Chime On/Off
This function key provides the user a simple method for
turning the Door Chime feature on and off ( see section '[*]
[4] Door Chime On/Off' ) .
[07] - [*]+[6]...[4] System Test
This function key provides the user with a simple method
for testing the system ( see section '[*] [6] User Functions' ) .
A valid Master Code is required to perform this com-
mand.
[08] - [*]+[1] Bypass Mode
This function key provides the user with a simple method
for entering the Bypass Mode. If an access code is
required it must be entered before bypassing can be per-
formed ( see section '[*][1] Zone Bypassing' ) .
[09] - [*]+[2] Trouble Display
This function key provides the user with a simple method
for entering the Trouble Display mode ( see section '[*][2]
Trouble Display').
[10] - [*]+[3] Alarm Memory
This function key provides the user with a simple method
for entering the Alarm Memory Display mode ( see sec-
tion '[*] [3] Alarm Memory' ) .
[11] - [*]+[5] Programming Access Codes
This function key provides the user with a simple method
for programming access codes. After this key is pressed a
valid System Master or Supervisor Code will have to be
entered before the panel will allow programming to be
performed (see section 4.2 '[*] Commands') .
[12] - [*]+[6] User Functions
This function key provides the user with a simple method
for programming user functions. Once this key is pressed a
valid System Master Code or Partition Master Code must
be entered before the panel will allow User Functions to be
performed (section 4.2 '[*] Commands') .
[13] - [*]+[7]+[1] Command Output Option 1
This function key provides the user with a simple method
for activating a PGM output programmed as Command
Output Option 1 (see Section 5.8, Programmable Output
Programming) . By default, after this key is pressed a valid
access code must be entered (section 4.2 '[*] Commands') .
[14] - [*]+[7]+[2] Smoke Detector Reset
This function key provides the user with a simple method
for activating a PGM output programmed as either option
[03] Sensor Reset or [20] Command Output option 2.
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power832Pc5010 cp-01