[377] - COMMUNICATION VARIABLES
Test Transmission Cycle (LINKS1000)
This value determines the period between Test Transmissions for the LINKS1000. Valid entries are [000]-[255]. The period is in days or hours. This applies to
Land-line and LINKS Test Transmissions, and for minutes and hours for the Land-line (LINKS only uses Hours).
NOTE: When a new value is programmed (locally or remotely), the panel will transmit a Test transmission when the next Test Transmission Time
is reached. The panel will then load in the new value, and continue the cycle based on this new value. This informs the Installer/Central to expect
the next Test Transmission when the cycle has been changed.
Wireless Zone Low Battery Transmission Delay (Days)
When a zone reports a low battery condition, the Trouble condition will be indicated immediately on the keypad, but the transmission to the monitoring station
will be delayed by the number of days programmed in this section. If the user does not correct the low battery condition before the delay expires, the low bat-
tery condition will be transmitted. The Low Battery Restoral transmission is not delayed.
NOTE: The panel will not send additional low battery events until the first low battery Trouble is restored.
Delinquency Transmission Delay
The value in this section determines the period of time that the Delinquency Event will be postponed until it is logged to the event buffer and transmitted.
Whether this value is in hours or days is determined if Delinquency is for Activity (hours) or Closing (days) as specified in Section [380] Option 8.
The timer starts under the following conditions:
• When the system is armed in the Stay mode
• When the system is disarmed
• When a zone is violated and restored while the system is disarmed/Stay armed (Interior, Interior Delay, Interior Stay/Away, or Delay
Stay/Away zones only).
The activity delinquency timer will be ignored when the system is armed in the Away mode. Zones that are bypassed in the [*][1] Bypass
menu will not reset the timer.
If the system is programmed to monitor Closing Delinquency
system is disarmed.
Activity/Closing Delinquency section [380], option [8].
Communications Cancel Window
After TX Delay expires and a zone alarm has been transmitted, the Cancel window will begin. If an access code is entered during this window, a Communica-
tions Cancel reporting code will be communicated. If the window expires without an access code entered or a code is entered after the window, no Opening
After Alarm log or communication will occur. The system keypads will provide an audible confirmation that the opening after alarm log was successfully com-
municated (5 quick beeps).
[378] - Test Transmission Time of Day
Program the time of the test transmission in this section.
Enter a 4-digit time using the 24-hr clock format
(HH:MM). Valid entries are from 00 to 23 for the hours
(HH) and 00 to 59 for the minutes (MM).
[380] - FIRST COMMUNICATOR OPTION CODES
Option
Communicator Code
1
Communications
2
Restore Transmission
3
Dialing Method
4
Switch to Pulse Dialing
5
3rd Phone Number Enable
6
3rd Phone Number
7
LINKS Dialing
P r o g r a m m i n g S e c t i o n s : 5 . 6 C o m m u n i c a t o r P r o g r a m m i n g P W S S e c t 6
Closing Delinquency, the timer will be programmed in days. The timer will restart every time the
Closing Delinquency
Closing Delinquency
On/Off
Description
ON
Communicator Enabled. The system's communicator will be enabled and all events with
reporting codes will be reported to the monitoring station. Refer to the Telephone Number,
reporting code and Call Direction Programming Sections.
OFF
Communicator Disabled. The system's communicator will be shut off and events will not be
transmitted to the monitoring station. Downloading may still be performed if enabled.
ON
Restore Transmissions on Bell Time-out. Zone restoral reporting codes will not be transmit-
ted until the zone has been restored and the Bell time-out has expired. If the zone is not
restored when the bell time-out expires, the restoral will be transmitted when the zone physi-
cally restores or when the system is disarmed.
NOTE: 24-hr zones will not restore until the zone is physically restored.
OFF
Restore Transmissions Follow Zones. Zone restoral reporting codes will be transmitted when
the zone is physically restored. If the zones are still active when the system is disarmed, the
restore codes will be transmitted when the system is disarmed.
NOTE: 24-hr zones will not restore until the zone is physically restored.
ON
Pulse Dialing enabled. The control panel will dial telephone numbers using pulse (rotary) dialing.
OFF
DTMF Dialing enabled. The control panel will dial telephone numbers using DTMF (dual tone
multi-frequency) dialing.
ON
Switch to Pulse Dialing after 4 DTMF attempts. If DTMF dialing is enabled, the control panel
will dial telephone numbers using DTMF dialing for the first 4 attempts. If unsuccessful, the con-
trol panel will switch to pulse (rotary) dialing for the remaining attempts.
OFF
DTMF Dial for all Attempts. If DTMF dialing is enabled, the control panel will dial telephone
numbers using DTMF dialing for all dialing attempts.
ON
3rd Phone Number Enabled. The 3rd Phone number will be used for Alternate Dialing with
the 1st phone number or as a backup of the 1st phone number (see light 6).
OFF
3rd Phone Number Disabled. The 3rd Phone number will not be used.
ON
Alternate Dialing Enabled (1st & 3rd). After each dialing attempt, the communicator
switches between the 1st phone number and 3rd phone number.
OFF
Call 1st Number, Backup to 3rd Number. If the programmed number of attempts to commu-
nicate to the First Telephone Number fail, the same number of attempts will be made to com-
municate to the Third Telephone Number. If all attempts to communicate to the Third Telephone
Number fail, a Failure to Communicate Trouble will be generated.
ON
Call LINKS as well as Land Line(s). The control panel will dial the programmed number of
attempts through the LINKS, followed by the number of programmed attempts over the land-
line regardless of whether the communication over the LINKS was successful.
WWW.DIYALARMFORUM.COM
To disable the test transmission, enter [9999] in this sec-
tion.
NOTE:
Do NOT enter [9999] for Central & Remote Fire