[903] - Module Supervision Field
When this mode is entered, the system will display all of
the modules presently enrolled on the system as indicated
below.
[903] MODULE SUPERVISION FIELD
Indicator
Lights 1-8
Lights 9-11
Zone Expander Groups 1-3
Light 15
Light 17
Light 18
Light 19
Light 20
Light 21
Light 22
Alternate Communicator (i.e. DVACS, Skyroute)
Light 23
Downlook Module
Light 24
Light 25
Light 26-29
[904] - Module Placement Test
Module Selection
Module Selection
Module Selection
Module Selection
Upon entering Section [904], a 2-digit entry will be
required to select the zone number to be tested. Valid
entries are 01-32 for Zones 01-32 respectively. On an LCD
keypad, there are two ways to make a zone selection:
direct entry of 01-32, or by scrolling across to the descrip-
tion of the module (i.e. 'Zone 1'). If a module is selected
that is not enrolled, an error tone will sound.
Placement Indication
Placement Indication
Placement Indication
Placement Indication
After the zone is selected, the alarm contacts must be
opened. This will register a signal strength value that will
be indicated and anunciated on all keypads, as well as on
the bell. The system will remain in this test mode until [#]
is pressed or Installer Time-out (20 minutes).
• GOOD
GOOD signal will be indicated by Light 1 on an LED
GOOD
GOOD
keypad or the word GOOD on an LCD keypad. It will be
enunciated on the Keypad by 1 beep and on the Bell by 1
Squawk.
• FAIR
FAIR signal will be indicated by Light 2 on an LED key-
FAIR
FAIR
pad or the word FAIR on an LCD keypad. It will be
enunciated on the Keypad by 2 beep and on the Bell by 2
Squawk.
• BAD
BAD
BAD signal will be indicated by Light 3 on an LED key-
BAD
pad or the word BAD on an LCD keypad. It will be enun-
ciated on the Keypad by 3 beep and on the Bell by 3
Squawk.
• Non-Enrolled zone will be annunciated on the Keypad
by an error tone.
[906] - Local Downlook Remote Trigger
While in this section, either 1 or 2 can be pressed to ini-
tiate Downlook to either phone number 1 or 2, respec-
tively. The panel will communicate the System Test event,
log 'Downlook Remote Trigger', and transmit the script
found in the PC5108L for Remote Trigger.
[990][Installer Code] - Installer Lockout Enable
If enabled, the panel will give a distinctive audible indica-
tion on power up (the phone line relay will click 10
times). This feature will have no effect on a Software
Default (all programming will return to the factory
defaults). However, if a Hardware default is attempted
while lockout is enabled, the default will not occur, and
the fraudulent attempt will be logged to the event buffer.
P r o g r a m m i n g S e c t i o n s : 5 . 1 1 S p e c i a l I n s t a l l e r I n s t r u c t i o n s P W S S e c t 1 1
Module
Keypads 1-8
PC5100
PC5132
PC5208
PC5204
PC5400
PC59XX
Escort5580(TC)
For Future Use
PC520X1-4
WWW.DIYALARMFORUM.COM
Installer Lockout
If Installer Lockout
Installer Lockout is selected a hardware default cannot
Installer Lockout
Installer Lockout
be performed. If a software default is performed all pro-
gramming will restore to factory default.
When Installer Lockout Disable
Installer Lockout Disable is selected the panel will
Installer Lockout Disable
Installer Lockout Disable
restore all programming to factory defaults if a hardware
or software default is performed on the main control panel.
To enable Installer Lockout perform the following:
1.Enter Installer Programming.
2.To enable Installer Lockout, enter section [990]
3.Enter the Installer Code.
4.Enter section [990] again.
[991][Installer Code] - Installer Lockout Disable
This disables the Installer Lockout feature described above.
To disable Installer Lockout perform the following:
1. Enter Installer Programming.
2. To disable Installer Lockout, enter section [991].
3. Enter the Installer Code.
4. Enter section [991] again.
[993]-[999] Factory Defaults
On occasion it may be necessary to default the main con-
trol panel or one of the modules that can be connected.
There are several different defaults available including
defaulting the main control panel, Escort5580(TC) mod-
ule, PC5132 wireless expander module, PC5400 printer
module and LINKS2X50 module.
NOTE:
Defaulting the main panel does not default the
keypads. See the Programming Worksheets Appendices A
and B for instructions for defaulting LCD5500Z/LCD5520Z
and LCD5501Z keypads. PC55XXZ LED keypads must be
manually reprogrammed in programming section [000].
Factory Default Main Panel (Hardware)
1. Remove AC and battery power from the panel.
2. Remove all wires from the zone 1 and PGM1 terminals.
3. With a piece of wire short the zone 1 terminal to the
PGM1 terminal.
4. Apply AC power to the main panel.
5. When zone light 1 is lit on the keypad the default is com-
plete.
6. Remove AC power from the control
7. Reconnect all original wiring and power up the control.
NOTE:
AC power must be used to power the panel. The
panel will not default if the battery is used.
Factory Default Main Panel (Software) and other
modules
1. Enter Installer Programming.
2. Enter the appropriate programming section [99X].
3. Enter the Installer Code.
4. Enter the appropriate programming section [99X] again.
The panel will take a few seconds to reset. When the key-
pad is operational, the default is complete.
[993][Installer Code] - Restore Alternate Comm.
Factory Default Programming
When this section is successfully entered, all program-
ming for the Alternate Communicator (LINKS2150,
LINKS2450, LINKS3000, or PC5400 DVACS module) will
be returned to the factory defaults.
[994][Installer Code] - Restore PC5100 2-Wire
Addressable Device Interface Factory Default Pro-
gramming
When this section is successfully entered, all program-
ming in the PC5100 2-wire addressable device interface
module will be returned to the factory defaults.
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power832Pc5010 cp-01

Table of Contents