Section #
Reporting Code
[344]
Special Opening
[345]-[346]
Battery Trouble/Restoral
[345]-[346]
AC Line Trouble/Restoral
[345]-[346]
Bell Circuit Trouble/Restoral
[345]-[346]
Fire Trouble/Restoral
[345]-[346]
Auxiliary Power Trouble/Rest.
[345]
TLM Failure
[346]
TLM Restore
[345]-[346]
Gen System Trouble/Restoral
[345]-[346]
Gen System Supervisory Trou-
ble/Restoral
[347]
Phone# 1 or 2 FTC Restoral
[347]
Event Buffer is 75% Full
[347]
DLS Lead In
[347]
DLS Lead Out
[347]
Zone Fault/Rest.
[347]
Delinquency
[347]
Wireless Device Low Battery
Trouble/Rest.
[347]
Installer Lead In
[347]
Installer Lead Out
[348]
Walk Test End
[348]
Walk Test Begin
[348]
Periodic Test with Trouble
[348]
Periodic Test
[348]
System Test
[348]
LINKS1000 Test
[349]
PC5700 Ground Fault Trouble/
Restoral
[349]
PC5700 TLM Line 1 Trouble/
Restoral
[349]
PC5700 TLM Line 2 Trouble/
Restoral
*
A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
**
UU = user number (user01-42); ZZ = zone number (01-32)
***
Use the Fail to Close event code [(4)54] to report closing or activity delinquency. Ensure the central station is aware that this code is used.
****
Zones are identified; panic pendants, wireless keys, and handheld keypads are not.
Code Sent When...
Opening (disarming) using one of the following methods: key-
switch, maintenance code, DLS software, wireless key
PC5010 CP-01 battery is low/battery restored
AC power to control panel is disconnected or interrupted/AC
power restored (Both codes follow AC Failure Comm. Delay.)
Open or short circuit detected across bell terminals/bell circuit
restored
Trouble occurs/restores on a fire zone
Aux voltage supply trouble/restoral
Telephone line monitoring trouble (sent via LINKS1000. Do not
program if LINKS1000 not used)
Telephone line restored
'Service Required' Trouble occurs (view troubles using [*][2])/
trouble restored
Control panel loses/restores communications with module(s)
connected to the Keybus
Control panel has restored communications to central station
on Phone# 1 or 2 (after FTC)
Event buffer is almost full since last upload
Downloading session start
Downloading session complete
One or more zones have faults/restored
Programmed amount of time (days or hours) for delinquency
has expired without zone activity, or without system being
armed
Wireless zones, panic pendants, handheld keypads, wireless
keys have low battery/all low batteries restored
Installer Programming has been entered
Installer Programming has been exited
End of test
Beginning of test
Periodic system test transmission with trouble
Periodic system test transmission
[*][6] bell/communications test
LINKS1000 test transmission
Ground/Fault/Trouble occurs on the PC5700
TLM Trouble /Restoral occurs on the PC5700
TLM Trouble /Restoral occurs on the PC5700
WWW.DIYALARMFORUM.COM
Dialer
Direction*
O/C
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
T
T
T
T
T
T
MA/R
MA/R
MA/R
49
Automatic
SIA Auto
Contact ID
Reporting
Codes
Codes**
(4) AA
OP-00
(3) A2
YT-00/YR-00
(3) A1
AT-00/AR-00
(3) 21
YA-99/YH-99
(3) 73
FT-00/FJ-00
(3) AA
YP-00/YQ-00
(3) 51
LT-00
(3) 51
LR-00
(3) AA
YX-00/YZ-00
(3) 33
ET-00/ER-00
(3) 54
YK-00
(6) 23
JL-00
(4) 11
RB-00
(4) 12
RS-00
(3) 72
UT-ZZ/UJ-ZZ
(4) 54***
CD-00
(3) 84
XT-00/XR-00
XT-ZZ/XR-ZZ****
(6)27
LB-00
(6)28
LS-00
(6) A7
TS-00
(6) A7
TE-00
(6) A8
RP-01
(6) A2
RP-00
(6) A1
RX-00
(6) A3
TX-00
(3) 1A
US-00
(3) 51
LT-XX
(3) 52
LR-XX