Wiring Precautions
Be sure to follow these instructions when wiring the unit:
a)
Do not wire the telephone cable in parallel with an AC power source, computer, telex,
etc. If the cables are run near those wires, shield the cables with metal tubing or use
shielded cables and ground the shields.
b)
If cables are run on the floor, use protectors to prevent the wires from being stepped on.
Avoid wiring under carpets.
c)
Avoid using the same power supply outlet for computers, telexes, and other office
equipment. Otherwise, the system operation may be interrupted by the induction noise
from such equipment.
d)
Please use one pair telephone wire for extension connection of (telephone) equipment
such as single line telephones, data terminals, answering machines, computers, voice
processing systems, etc., except Panasonic proprietary telephones (e.g. KX-T7536, KX-
T7235).
e)
The Power Switch of the system must be off during wiring. After all of the wiring is
completed, turn the Power Switch on.
f)
Mis-wiring may cause the system to operate improperly. Refer to Section
6.1.1 Installation and 6.1.2 Connection.
g)
If an extension does not operate properly, disconnect the telephone from the extension
line and then connect again, or turn off the Power Switch of the system and then on
again.
h)
The system is equipped with a 3-wire grounding type plug. This is a safety feature. If
you are unable to insert the plug into the outlet, contact your electrician to replace your
obsolete outlet. Do not defeat the purpose of the grounding-type plug.
i)
Use twisted pair cable for outside line connection.
j)
Outside lines should be installed with lightning protectors. For details, refer to Section
2.3.9 Installation of Lightning Protectors.
WARNING
Static sensitive devices are used. To
protect printed circuit boards from
static electricity, do not touch
connectors indicated to the right.
To discharge body static, touch
ground or wear a grounding strap.
General Installation
Warning: Static sensitive connectors
KX-TD1232
2.1 Before Installation
KX-TD816
35