CSP-100 SPECIFICATION
SIMPLIFIED EIA RS-232 TO CENTRONICS INTERFACE
Input
Asynchronous Serial Data EIA-Level
1 Start Bit
7 Data Bits plus Parity
or
8
Data Bits
1 or 2 Stop Bits
See Back
<Output
. Parallel Data TTL Centronics
Compatible
Busy*
Busy enabled Low Level
Not Busy High Level
Inverted Busy*
Inverted Busy enabled High Level
Not Busy Low Level
Baud Rates
300, 600, 1200, 2400, 4800
&
9600
Baud Strappable
See Back
EIA Signal Connector
Male 25 Pin AMP (Standard EIA)
Cable length - 10'
Printer Input
&
Output Connector
Male 36 Pin AMP (Centronic Standard)
Cable Length 12"
Power
Powered from Centronics Printer
less than 400
MA@ 5
Volts
Operating Temperature
+5
0
C to 50
0
C
Relative Humidity 5% to 95%
without condensation
Mounting
Self Adhesive
Size
3 7/8" W x 5 3/4" L x 1 1/4" H
Molded Plastic'
Weight
13 oz.
1 1/4 lbs. shipping weight
Option
Baud Rate Switch
Word Structure Switch
Since the Model CSP-100 is not buffered it may be necessary to place two Null
Characters after carriage return in order not to lose data due to delay in
Busy Signal.
*Two spare leads, with pins attached, are located inside EIA Connector Hood.
These leads may be used to change pin assignments.
For example;
to change
busy from pin 20 to pin 11, you would simply snap one of the spare wires
into hole 11 on the EIA Connector and then replace the orange or brown (busy,
inverted busy) wire at the Circuit Board with selected spare.
Tape the removed
orange or brown wire.
Unit is strappable for busy or inverted busy.
See back.