Trip Limits/Trip Times - SMA SUNNY BOY 5000-US Installation Manual

Pv inverter
Hide thumbs Also See for SUNNY BOY 5000-US:
Table of Contents

Advertisement

Technical Data

11.6 Trip Limits/Trip Times

Frequency
Nominal
Frequency
60 Hz
< 57.0 Hz ... 59.8 Hz
(standard 59.3 Hz)
Voltage
Nominal
Trip Limit
Voltage
208 V
240 V
277 V
* The intervals result from the measuring accuracies listed below.
Accuracy
Trip limits: ±2 % of nominal grid voltage
Trip time: ±0.1 % of nominal trip time
Trip frequency: ±0.1 % of nominal frequency
100
SB50US-80US-IA-en-36
Trip Limit
> 60.5 Hz
< 57.0 Hz
Trip Voltages
Conductor-
Neutral
Conductor*
50 %
57.6 V ... 62.4 V
88 %
103.2 V ... 108.0 V
110 %
129.6 V ... 134.4 V
120 %
141.6 V ... 146.4 V
50 %
57.6 V ... 62.4 V
88 %
103.2 V ... 108.0 V
110 %
129.6 V ... 134.4 V
120 %
141.6 V ... 146.4 V
50 %
133.0 V ... 144.0 V
88 %
238.2 V ... 249.3 V
110 %
299.2 V ... 310.2 V
120 %
326.9 V ... 337.9 V
Trip Frequencies
60.45 Hz ... 60.55 Hz
56.95 Hz ... 59.85 Hz
(standard 59.25 Hz ...
59.35 Hz)
56.95 Hz ... 57.05 Hz
Trip Voltages
Conductor-
Conductor*
99.8 V ... 108.2 V
178.9 ... 187.2 V
224.6 V ... 233.0 V
245.4 V ... 253.8 V
115.2 V ... 124.8 V
206.4 V ... 216.0 V
259.2 V ... 268.8 V
283.2 V ... 292.8 V
Not applicable
SMA America, LLC
Trip Times
max. 0.1602 s
adjustable, 0.16 s ... 300 s
(standard max. 0.1602 s)
max. 0.1602 s
Trip Times
max. 0.1602 s
max. 2.002 s
max. 1.001 s
max. 0.1602 s
max. 0.1602 s
max. 2.002 s
max. 1.001 s
max. 0.1602 s
max. 0.1602 s
max. 2.002 s
max. 1.001 s
max. 0.1602 s
Installation Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sunny boy 6000-usSunny boy 7000-us