PIAGGIO NRG Power DT Workshop Manual page 56

Nrg power dt 633257
Table of Contents

Advertisement

Electrical system
4. Battery not recharging.
5. Turn signals not operational.
6. Dashboard check not operational.
Interventions
FAULT 1
Replace the regulator as definitely faulty.
FAULT 2
a) Check the output from the stator gives the cor-
rect voltage: detach the stator connector, inter-
pose an AC tester between the grey-blue and
black cables, and check the output voltage is with-
in the prescribed limits. If anomalies are found,
replace the stator.
b) If no anomalies are identified, replace the reg-
ulator.
c) If the replacement of the regulator does not
solve the fault, check the electric connections.
Specific tooling
020331Y Digital multimeter
Characteristic
Voltage distributed at 3000 rpms
25 to 30V
FAULT 3
After checking that there are no short circuits in the
system towards the earth, replace the regulator
because it is certainly inefficient and replace it with
a protective fuse.
Following the replacement, measure the current
and the recharging voltage on the battery end.