Set the heating

It is easy to set the heating level on the heat pump. However, before we
explaaccord. to clockow to do this it is important to understand the relation
between the outdoor temperature, return temperature and heat curve
slope. The easiest way to explain the relation is with a heat curve.
Heat cur ve
You use the heat curve to help set the indoor temperature you would
like. The heat pump is controlled by the outdoor temperature. When the
weather becomes colder, the heat pump ensures more heating is produced
automatically.
Return temperature:
The return temperature is the temperature of the water that returns to the
heat pump from the radiators. The water led out from the heat pump to the
heating system is normally 7-10ºC higher than the return temperature.
When the outdoor temperature is -10ºC and curve 4 is set, the pump
attempts to keep the return water at approximately 40ºC.
Outdoor temperature:
The outdoor temperature determines how much heating the heat pump
should produce. A sensor placed outdoors sends signals to the control unit,
which then adjusts the heat pump.
Cur ve slope:
You can change the curve slope to increase or decrease the heating in the
house. The scale is between 0-10.
On delivery the heat pump curve
slope is set to position 4. This means
that the return temperature is +35ºC
when it is 0ºC outdoors.
15
Basic functions - Customer level 1
STANDBY
No rad heat required
No need
for hot water mode
HOTWATER MODE
Heat pump only
Supp. temp.
53,0°
Present temp
42.0°
HEATING Mode
HP and add. heat
Supp. temp.
45,0°
Present temp
44.0°
Heat rad required
Heat pump starts
in 320 seconds