Bosch Compress 7001i AW Installation Manual

Bosch Compress 7001i AW Installation Manual

Air to water heat pump
Hide thumbs Also See for Compress 7001i AW:

Advertisement

Installation Manual
Air to Water Heat Pump
Compress 7001i AW
5-17 OR-S/T

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Compress 7001i AW

  • Page 1 Installation Manual Air to Water Heat Pump Compress 7001i AW 5-17 OR-S/T...
  • Page 2: Table Of Contents

    / three-phase current ....27 9.5.2 Wiring diagram for I/O module card ....28 Compress 7001i AW – 6721835318 (2021/09)
  • Page 3: Explanation Of Symbols And Safety Instructions

    All other use is backflow) considered unsuitable. Any damage that is caused by • EN 378 (Refrigerating systems and heat pumps - Safety and such usage is excluded from liability. environmental requirements) Compress 7001i AW – 6721835318 (2021/09)
  • Page 4: Water Quality

    When installing diffusion open pipes, a system separation with the help of a heat exchanger is required. ADEY 01242 546700 www.adey.com FERNOX 0330 100 7750 www.fernox.com SENTINEL 01928 704330 www.sentinelprotects.com/uk Table 3 1) Only applicable in the United Kingdom. Compress 7001i AW – 6721835318 (2021/09)
  • Page 5: Product Description

    Declaration of conformity Heat pump details The design and operating characteristics of this product comply with the The Compress 7001i AW heat pumps are intended for connection to the European and national requirements. AWM/AWMS or AWE/AWB indoor units. The CE marking declares that the product complies with all the...
  • Page 6: Product Overview

    Dimensions and connections of heat pump models 5 OR-S-9 Pressure switch/pressure sensor OR-S compressor Inverter Description applies for all sizes. ø10,5 Fig. 5 Dimensions of heat pump models 5 OR-S-9 OR-S, view from top Compress 7001i AW – 6721835318 (2021/09)
  • Page 7: Dimensions Of Heat Pump Models 13 Or-S

    Clearances during setup The clearance can be reduced on one side. This may however lead Installation clearances of heat pump with sound insulation to a higher noise level. (accessory). Installation clearances of heat pump. Compress 7001i AW – 6721835318 (2021/09)
  • Page 8: Preparing For Installation

    – Protect the air intake side by a wall or similar object to avoid having strong winds blowing straight through the heat pump. Fig. 10 Free standing heat pump Compress 7001i AW – 6721835318 (2021/09)
  • Page 9: For Drainage

    (radiators) and concrete floor (underfloor heating system). As the requirements for different heat pump installations and heating systems vary considerably, a minimum water volume in litres is generally Compress 7001i AW – 6721835318 (2021/09)
  • Page 10: Installation

    Fig. 13 Transport fitting Transport fitting Red marking Fig. 14 Fastening the heat pump Adjustable feet 4 pieces M10 X120 mm (not included in scope of delivery) Level subsurface with sufficient load bearing capacity, e.g. concrete foundations Compress 7001i AW – 6721835318 (2021/09)
  • Page 11: Connection

    ▶ Insulate the particle filter and also the other connections. Fig. 16 Pipe length A ▶ Establish the connection to the heat pump using a vibration-damping Indoor unit wall mounted hose which is suitable for use outdoors and also insulate it. Heat pump Compress 7001i AW – 6721835318 (2021/09)
  • Page 12 3) This pipe length applies if a diverter valve is not installed in the DHW circuit of the system. Table 8 Pipe dimensions and maximum pipe lengths (single section) for connecting the heat pump to the AWE indoor unit with integrated electric booster heater Compress 7001i AW – 6721835318 (2021/09)
  • Page 13: Water Connecting Pipe

    ▶ When changing the PCB, note the colour coding. ▶ Use pipes in accordance with Chapter 5.5.1. ▶ Connect flow to the indoor unit at the heat transfer medium outlet of the heat pump ( [1], Fig. 18). Compress 7001i AW – 6721835318 (2021/09)
  • Page 14 ▶ Reattach the cover of the control device. ▶ Reattach the belt. Fig. 20 Cable conduits and control device Cable conduit, power supply 1-phase heat pump Cable conduit CAN-BUS Connection CAN-BUS 3-phase heat pump Compress 7001i AW – 6721835318 (2021/09)
  • Page 15: Installing Side Panels And Cover

    Installation Installing side panels and cover 0010020097-002 Fig. 21 Installing side panels and cover Compress 7001i AW – 6721835318 (2021/09)
  • Page 16 Installation 0010020098-003 Fig. 22 Installing side panels and cover Compress 7001i AW – 6721835318 (2021/09)
  • Page 17: Maintenance

    The electronic expansion valves are highly sensitive to impacts. Install power cable ▶ Always protect the expansion valve from impacts and shock. ▶ Check the power cable for mechanical damage. ▶ Replace damaged cables. Installation of accessories Heating cable Compress 7001i AW – 6721835318 (2021/09)
  • Page 18 Installation of accessories Compress 7001i AW – 6721835318 (2021/09)
  • Page 19: Environmental Protection And Disposal

    For additional information on the environmentally compatible disposal of old electrical and electronic appliances, please contact the relevant local authorities, your household waste disposal service or the retailer where you purchased the product. You can find more information here: www.weee.bosch-thermotechnology.com/ Compress 7001i AW – 6721835318 (2021/09)
  • Page 20: Technical Information

    Dimensions (W x H x D) 930x1380x440 930x1380x440 930x1380x440 1122x1695x545 Weight without walls and top cover Weight with walls and top cover 1) Performance data in accordance with EN 14511 2) Fuse class gL/C Compress 7001i AW – 6721835318 (2021/09)
  • Page 21 <3 m dB (A) 1) Heat pump more than 3 m from the wall 2) Heat pump closer than 3 m to the wall Table 14 Detailed sound pressure level, heat pump (alternating current) Compress 7001i AW – 6721835318 (2021/09)
  • Page 22 5 OR-S 7 OR-S 9 OR-S 13 OR-S Max. sound power dB(A) Max. sound power “quiet dB(A) operation” Table 18 Acoustic performance data – heat pump (three-phase current) with sound insulation at front and back Compress 7001i AW – 6721835318 (2021/09)
  • Page 23: Specifications - Heat Pump (Three-Phase Current)

    Weight with walls and top cover 1) Performance data in accordance with EN 14511 2) Fuse class gL/C 3) Sound power level in accordance with EN 12102 4) GWP100 = 2088 Table 19 Specifications – heat pump (three-phase current) Compress 7001i AW – 6721835318 (2021/09)
  • Page 24 1) Heat pump more than 3 m from the wall 2) Heat pump closer than 3 m to the wall Table 23 Detailed sound pressure level of heat pump incl. acoustic covers at front and back (accessories) <3m >3m Compress 7001i AW – 6721835318 (2021/09)
  • Page 25: Operating Range Of Heat Pump Without Auxiliary Heater

    – 17 °C or falls below +32 °C. In cooling mode the heat pump switches off at roughly +45 °C and restarts at roughly +42 °C. T0[°C] T1[°C] Fig. 23 Heat pump without auxiliary heater Maximum flow temperature (T0) Outdoor temperature (T1) Compress 7001i AW – 6721835318 (2021/09)
  • Page 26: Refrigerant Circuit

    Temperature sensor, condenser return (liquid), heating mode [TR4] Temperature sensor, evaporator return (liquid), cooling mode [TR5] Temperature sensor, suction gas [TR6] Temperature sensor hot gas [VR0] Electronic expansion valve 2 (condenser) [VR1] Electronic expansion valve 2 (evaporator) [VR4] Four-way valve Compress 7001i AW – 6721835318 (2021/09)
  • Page 27: Wiring Diagram

    Fig. 25 Wiring diagram for transformer, alternating current / three-phase current [ER1] Compressor [MR1] High pressure switch [V1] EMC filter, only for 13kW 1N~ Inverter Mains voltage 230V 1N~ (5-13kW) Mains voltage 400V 3N~ (13-17kW) Power supply of I/O module MOD-BUS to I/O module Compress 7001i AW – 6721835318 (2021/09)
  • Page 28: Wiring Diagram For I/O Module Card

    CAN-BUS from installation module of indoor unit [VR1] Electronic expansion valve 2 [EA0] Heater for drip pan [EA1] Heating cable (accessory) [F50] Fuse 6.3A [PL3] [SSM] Motor protection in the fan [VR4] Four-way valve Compress 7001i AW – 6721835318 (2021/09)
  • Page 29: Measurements For Temperature Sensor

    Information for the installer: If you refill refrigerant, enter the additional charge size and the total charge size of the refrigerant in the table “information on refrigerant” of the operating instructions. Compress 7001i AW – 6721835318 (2021/09)
  • Page 32 CONTROLS AND CONNECTIVITY TEAM: 0330 123 3641 APPOINTMENTS: 0330 123 9339 SPARES: 0330 123 9779 LITERATURE: 0330 123 9119 TRAINING: 0330 123 0166 SALES: 0330 123 9669 Bosch Thermotechnology Ltd. Cotswold Way, Warndon Worcester WR4 9SW United Kingdom Tel. 0330 123 9559 worcester-bosch.co.uk...