Extra Functions (Customer Level 2); Menu Outline For Extra Functions (Customer Level 2) - Bosch EHP 6-11 LW User And Installation Manual

Heat pump compress 3000
Table of Contents

Advertisement

Extra functions
The section Basic functions (Customer level 1) contains the functions that you will
probably use the most and which you will receive the most benefi t from. However,
there are numerous extra functions that you can use to control your heat pump.
This can, for example, include activating the heat pump's holiday function or
setting the time and date. If no settings are made on Customer level 2 (K2), the
menu display will automatically return to Customer level 1 (K1) after 30 minutes.
Proceed as follows to access the extra functions on Customer level 2:
1. Press the Heat button until Access = CUSTOMER2 is displayed.
2. Press the Menu button to open the Main menu. From Customer level 2 you
also have access to all Customer level 1 functions.

Menu outline for Extra functions (Customer level 2)

Menu principal
Room temp. set-
Adjusting the hot
ting
1
water settings
Page 23
Heat curve
interval for
fi ne-tuning
1.3
hot water peak
Page 22
V3V +/-
interv. 0-10
1.5
Page 23
Adjust. V3V
range
-10/+10
1.6
Page 23
Adjust curve
V3V
1.7
Page 23
Setting of room
sensor infl
1.11
Page 22
Setting of holiday
function
1.12
Page 22
Remote control
temperature
1.13
Page 22
Setting of summer
disconnection
1.14
Page 22
(Customer level 2)
Reg 637
040622 16:08:15 Tu
temp.
Info
Main menu
Main menu
Timer control
2
settings
Page 24
Clock setting HP
2.2
accord. to clock 4.1
Page 24
Setting level
heat pump +/-
Clock setting DHW
accord. to clock 4.3
The menu display is standard
=
on all heat pumps.
=
The menu display is only
shown on the heat pump in
combination with an extra
sensor or for a specifi c model.
21
040622 16:08:15 Tu
temp.
Press the Heat button until Access
= CUSTOMER2 is displayed.
K2
Menu
Main menu
Op. time readings
4
HP and add. heat
Page 24
Page 25
Add. heat in operat.
number of hours? 7.1
Page 24
Page 26
Distribution HP
DHW-Rad in %
7.2
4.1.1
Page 25
Page 26
Add. heat in operat.
number of hours? 7.3
Page 25
Page 26
Note
From Customer level 2 you also have
access to all the basic functions on
Customer level 1.
Only the most frequently used menus
in Customer level 2 are shown in the
menu outline. All the menus cannot be
presented due to space limitations. Use
the dial to scroll through the menus.
Extra functions - Customer level 2
( Initial menu)
Reg 637
K2
Info
Menu
Main menu
Clock, setting
7
time and date
10
Page 27
Main menu
Alarm logging
of all alarms
11
Page 27
Main menu
Return to
factory settings
12
Page 27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehp 6-11 lm

Table of Contents