Bosch EHP 6-11 LW User And Installation Manual page 16

Heat pump compress 3000
Table of Contents

Advertisement

Basic functions - Customer level 1
Change the cur ve slope
The heat pump's production of heat is adjusted by increasing or decreasing
the curve slope in the Temp. incr. / decr. menu. This is especially effective
in cold weather conditions.
Return temperature (ºC)
Dashed line:
If the return temperature exceeds 57ºC an alarm is given and the compres-
sor switches off. The heat pump starts automatically when the return
temperature drops.
In cold weather (below +5ºC):
If you are not satisfi ed with the indoor temperature when it is colder than +5ºC
outdoors, you need to change the slope of the heat curve.
This is what to do:
1. Press the Heat button in the initial menu.
temp. +/-
0
4,0
Return
Adjust
2. Press the Adjust button.
3. Turn the menu dial clockwise to increase the heating.
Turn the menu dial anti-clockwise to lower the heating.
(Adjust in small increments, 0.2-0.6 units, is usually enough.)
temp. +/-
0
5,0
Return
4. Save the new value by pressing the Save button.
Outdoor temperature (ºC)
10
10
Save
Curve slope (0-10)
Cur ve slope:
2-4
4-6.5 Normal setting for radiators.
7-10
From the heat curve we see that
curve slope 4 gives a return tempera-
ture of +35ºC when it is 0ºC outdoors.
If the outdoor temperature drops we
can see that the return temperature
increases. The colder the outdoor
temperature the higher the return
temperature. At an outdoor tempera-
ture of approximately -30ºC we see
the curve slope has nearly reached
the limit value (+57ºC) for the return
temperature.
You should wait at least two days
when increasing or decreasing the
heating before making a new adjust-
ment.
If it is still diffi cult to get a comfort-
able indoor temperature at an outdoor
temperature around 0ºC, despite
several attempts, you should adapt
the heat curve. Read about how
to "adapt the curve" in the section
Extra functions – Customer level 2 /
Temperature settings / Adapting the
heat curve.
16
Normal setting for fl oor heating..
Abnormal high setting.
Note

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehp 6-11 lm