Operation; Shutting-Down; Main Menu; Heating Settings - Bosch CS5800iAW 180 MCP Operating Instructions Manual

Air to water heat pump pre plumbed cylinder
Hide thumbs Also See for CS5800iAW 180 MCP:
Table of Contents

Advertisement

Operation

The system overview shows the status of the heat pump and
temperatures in the system and surroundings.
1
2
3
4
5
10
Fig. 11 System overview
[1]
Key to return to the main menu
[2]
Display of date and time
[3]
Status display of Wi-Fi active, radio transmission active (for
wireless sensor) and internet connection active
[4]
Display of outdoor air temperature
[5]
Display of temperatures to and from the outdoor unit
[6]
Help menu
[7]
Display of flow temperature
[8]
Display of return temperature
[9]
Display of DHW temperature
[10] More..., for additional settings
More...
Menu item
Description
Settings
▶ Alternating operation. Select On to activate DHW
alternating operation. Select Off to deactivate
DHW alternating operation.
▶ Time prog., add. heater.
– Select On to activate time program. Select
Off to deactivate time program.
– Edit. Setting a time program for the booster
heater.
– Reset. To reset, press Yes. To return without
resetting, press No.
– Time prog. min. outdoor temp.. Select the
temperature limit to automatically disable the
booster heater program.
▶ Restore installer settings. To return to saved
installer settings, select Yes; to exit without
making any changes, select No.
Heat pump
▶ Shows the heat pump's operating status.
status
Statistics
▶ Shows the statistics for the heat pump
operation.
Table 2 More settings
8
3
Material damage from frost!
The heating or auxiliary heater may be irreparably damaged by frost.
▶ Do not start the heat pump if there is a possibility of the heating or
6
auxiliary heater being frozen.
An overview of the structure of the main menu and the position of the
7
individual menu items can be found at the end of this document.
8
The info menu is useful to get instant information of the status of the heat
9
pump.
Each of the following descriptions takes the standard display as its
starting point.
3.1
0010044162-001
The unit is normally switched on. The system is only switched off for
maintenance purposes, for example.
Standby means that the system is completely switched off and no safety
functions, such as frost protection, are active.
▶ To temporarily switch off the system:
– Select the option > Menu in the start menu
– Select Expert view > On for more menu options.
– Select Standby mode in the list
– Press Yes
▶ To switch on the system:
– Press on the display.
– Select Yes.
▶ To switch off the system permanently: interrupt the power supply to
the whole system and any additional accessories.
After a prolonged power failure or extended period of idleness, the date
and time must be reset. All other settings are retained permanently.
4
Depending on the heating appliance and how the user interface is used,
not all menu items will be available for selection.
4.1
Menu > Heating circuit 1
Menu item
Set operating
mode for Heating
circuit 1
Click on More... for additional settings.
Operation
WARNING

Shutting-down

Main menu

Heating settings

Description
▶ Select Off to switch off the heating circuit. Select
Auto for automatic control of the heating circuit
according to the time program. Select Manual to
set continuous operation of the heating circuit.
▶ Set the desired room temperature in this menu
by scrolling left or right on the scale. Save the
new setting with Confirm,
-or-
go back without making any changes with
Cancel.