Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized. Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Page 5
Failure to follow this warning will result in abrupt release of system charge and may result in personal injury and/ or property damage. Extreme caution should be exercised when applying gauges to service ports. Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
44-1/16" 11-3/4" Table 2 Unit Dimensions Heat Pump Model Net Weight Gross Weight BRBA-36HWD1N1-M18 400 lbs (182 kg) 420 lbs (191 kg) Table 3 Unit Weights Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Installation Instructions 3.3 Dimensions - Left and Top Top view Left side view 5-1/16" 6-5/8" 11-3/4" 6-5/8" Figure 4 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Cold climate considerations (heat pump only) NOTICE: Precautions must be taken for units being installed in areas where snow accumulation and prolonged below-freezing temperatures occur. Figure 5 1 0 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Page 11
Refer to local code requirements for additional Every three months, wash the outdoor coil and any exposed cabinet clearance requirements. surfaces. | 11 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
4 Speed Fan default is Tap (1), Tap (2), Tap (3), Tap (4) F or instructions on how to select fan speeds, refer to Section 6 of this manual. | 13 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Wiring Diagram section for wiring instructions. If Y1 and Y2 are jumped, the unit will only run in high stage fan speed. 1 4 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Be sure to note supply and return openings. Refer to Figure 3 for information concerning supply and return air duct dimensions. | 15 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
When making drain fitting connections to drain pan, do not overtighten. Over-tightening fi ttings can split pipe connections on the drain pan. 1 6 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
High voltage power supply Grounding may be accomplished by attaching ground wire(s) to ground lug(s) provided in the unit wiring compartment. Figure 17 | 17 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Page 18
Y2 wiring is optional for 4 speed fan control. For 2 stage fan control Y2 B wire must be used with heat pump system only, the reversing wiring is required. valve energizes in heating. 1 8 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
WARNING: ELECTRICAL SHOCK / FIRE HAZARD Any power supply and circuits must be wired and protected in accordance with federal, state and local electrical codes. Figure 22 | 19 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Calculate subcooling value on liquid line (According to Table 14) Measured Liquid Line Temp. = ________ºF Measured Liquid Line Pressure = _______ PSIG Calculate subcooling value = ________ºF 2 0 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Page 21
°F A dd refrigerant if the subcooling reading from Table 14 is Table 16 lower than the designed value (Table 15). | 21 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Low pressure protection (cooling mode) reduced short cycling. Accelerated cooling/heating function changes the initial target coil temperature to provide "enhanced comfort" by increasing unit capacity. 2 2 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
SW5-1 SW5-2 Remarks Operating time is Defrosting extended for reduced by 10% 60 seconds Normal Normal Default Remarks Enter defrost Quit defrost Table 18 | 23 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
If TF > 172°F, the compressor and outdoor fan will stop. ii. If TF < 160°F, the compressor and outdoor fan will restart. 2 4 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Always ON Normal Dehumidifi cation mode active Reserved Anti-cold air function active Temperature sensor fault (T1) Temperature sensor fault (T2) Communication error Table 20 | 25 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Only valid for 3T Indoor blower motor speed Only valid for 3T Ts (Estimated thermostat set point) (°F) Only valid for 3T Remark"--" Table 21 2 6 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
25. Compressor: V port 26. Compressor: U port 27. Power input 28. Power input 29. Non-replaceable Fuse 30. Ground port 31. Ground port Figure 32 | 27 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Page 28
Thermostat wire port (to ODU board) Transformer port Blower motor port T1, T2 sensor port Communication port (To ODU board) Reserve 3 Amp Replaceable Fuse Figure 33 2 8 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
10 mins Check whether the compressor current is more Replace the board than 15A for 2/3 ton when protected Replace the compressor Figure 36 | 29 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Page 30
Compare transducer the data between pressure measurement and No 9 (cooling) or No 10 (heating) values (by pressing the check button). Figure 38 3 0 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Page 31
No 9 (cooling) or No 10 (heating) check point value (by pressing check button) Check whether there is the Keep running same fault Figure 41 | 31 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Page 32
15V DC between the test Replace the control board point P & N Check whether there is Keep running the same fault Figure 45 3 2 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Page 33
The system will Replace the control board recover when the electric supply stabilizes. Figure 47 | 33 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Page 34
Figure 49 Pull out the pressure Replace pressure transducer connection, transducer check if there is any display Replace ODU board Figure 51 3 4 | Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
0 nor ∞ Restart the system Restart the unit to check if Finish Figure 53 the problem is resolved Replace indoor control board Figure 52 | 35 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Do not use benzene, paint thinner, polishing powder or other solvents to clean the unit. Do not operate the system without a filter in place | 39 Bosch 18 SEER2 Series Inverter Ducted Packaged Heat Pump - BTC 761703103 A (11.2022)
Page 40
United States and Canada Bosch Thermotechnology Corp. 65 Grove St. Watertown, MA 02472 Tel: 866-642-3198 Fax: 954-776-5529 www.bosch-thermotechnology.us BTC 761703103 A | 11.2022 Bosch Thermotechnology Corp. reserves the right to make changes without notice due to continuing engineering and technological advances.