Extra functions - Customer level 2

Hot water settings

Hot water peak
Recurring increase in the hot water temperature
The Range for hot water peak menu is used to set the range for a recurring
increase in the hot water temperature. This function takes the water tem-
perature temporarily up to approximately 65°C. Three settings are possible:
inactive (default), daily or preferred day.

Timer control

Open the setting menus for timer control like this:
1. Press the Heat button until Access = CUSTOMER2 is displayed.
2. Press the Menu button.
3. Turn the menu dial clockwise until you access the menu Timer control
settings (menu 4).
4. Press the Select button and scroll through the menus using the menu dial.
Clock setting of the heat pump according to clock
The function Clock setting HP accord. to clock is for those who want the heat
pump to produce different amounts of heat at different times of the day and
on different days of the week. This allows you to make further energy savings.
The room sensor T5 (GT5) infl uence is inhibited 24 hours after using clock
setting for the heating, or after any type of external control of the heat pump.
This allows the heating to return to ordinary settings. In practise this means
that should clock setting of the heating apply each night, then the room sensor
has no function except temperature readings.
Example:
You want to set the heat pump so that it maintains a 3ºC lower radiator tem-
perature on Mondays between 22:00 and 06:00.
1. Turn the dial clockwise until you access the menu Clock setting HP accord.
to clock (menu 4.1).
2. Press the Select button.
3. Turn the menu dial clockwise to choose the day. Now press the Adjust
button to select the weekday with the symbol ^. Turn the menu dial
clockwise one step to activate the start day. The weekday now has a capital
letter.
4. Press the right-hand arrow (->) until the cursor reaches the fi rst two zeros
(00).
When you have time based tariffs
with cheaper electricity for example
during the night, any savings may be
lost if the return to normal tempera-
ture occurs when the more expen-
sive electricity price applies.
24
Hot water
range for
hot water peak
2.2
Return
Select
Main menu
Indoor temperature
settings
1
Return
Select
Main menu
Timer control
accord. to clock
4
Return
Select
Note
Clock setting
Clock setting HP
accord. to clock 4.1
Return
Select
Timer control HP
1
Mon
00:00-00:00
Return
adjust
Timer control HP
1
Mon
00:00-00:00
Return
->
Timer control HP
1
Mon
00:00-00:00
Return
->